Foreword
Codeofchina com. is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.
This document is developed in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents.
This document was proposed and is under the jurisdiction of the National Technical Committee 114 of Auto Standardization (SAC/TC 114).
This document is issued for the first time.
Condenser for automotive air conditioning
1 Scope
This document specifies the technical requirements, test methods, inspection rules and marking, packaging, transportation and storage of condenser for automotive air conditioning (hereinafter referred to as condenser).
This document is applicable to external air-cooled condensers with HFC-134a and HFO-1234yf as refrigerants, heat pump-type interior air-cooled condensers and air-cooled condensers with liquid storage tanks.
2 Normative references
The following documents contain requirements which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 6287 Determination of static adsorbed water for molecular sieve
GB/T 10125 Corrosion tests in artificial atmospheres - Salt spray tests
GB/T 21361 Motor vehicle air-conditioning unit
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 21361 and the following apply.
3.1
Condenser
heat exchanger that cools and condenses gaseous refrigerant into a liquid
3.2
stable state
the state where fluctuation range of relevant test parameters is less than the specified value during the test
3.3
heat exchange
the heat emitted into the air by the condenser per unit time under the specified test conditions
3.4
air pressure drop
the pressure difference [1) Unless otherwise specified, the pressure in this document is gauge pressure.]1)between the inlet and outlet sides of the condenser when operating under specified test conditions
3.5
refrigerant pressure drop
the pressure difference between the refrigerant inlet and outlet of the condenser when operating under specified test conditions
3.6
subcooling condenser
heat exchanger that cools the high temperature and high pressure gaseous refrigerant entering the condenser into a high temperature and high pressure liquid refrigerant, and the liquid refrigerant at the outlet of the condenser has a certain degree of subcooling
4 Technical requirements
4.1 Dimensional tolerance and appearance requirements
When inspected in accordance with 5.1, the dimensional tolerances and appearance requirements of the products shall conform to the agreement between the seller and the buyer.
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Technical requirements
5 Test methods
6 Inspection rules
7 Marking, packaging, transportation and storage