Urban railway transportation platform screen door systen English
1 Scope
This standard specifies the technical requirements, tests, packaging, transportation and storage of urban railway transportation platform screen door system.
This standard is applicable to the design, manufacture, inspection and acceptance of urban railway transportation platform screen door system.
2 Normative References
The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated references, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties who enter into agreement according to this standard are encouraged to study whether the latest editions of these documents apply. For undated references, the latest edition applies to this standard.
GB 191 Packaging - Pictorial Marking for Handling of Goods
GB/T 699 Quality Carbon Structure Steels
GB/T 700 Carbon Structural Steels
GB/T 1220 Stainless Steel Bars
GB/T 1804-2000 General Tolerances - Tolerances for Linear and Angular Dimensions without Individual Tolerance Indications
GB/T 2828.1 Sampling Procedures for Inspection by Attributes - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for lot-by-lot Inspection
GB/T 3190 Wrought Aluminium and Aluminium Alloy - Chemical Composition
GB/T 3280 Cold Rolled Stainless Steel Sheets and Plates
GB/T 4171 Superior Atmospheric Corrosion Resisting Structural Steel
GB/T 4172 Atmospheric Corrosion Resisting Steel for Welded Structure
GB/T 4237 Hot Rolled Stainless Steel Sheets and Plates
GB 5237.1~5237.6 Wrought Aluminum Alloy Extruded Profiles for Architecture
GB/T 6388 Transport Package Shipping Mark
GB/T 7107 Graduation and Test Method for Air Performance of Windows
GB 9254 Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement
GB 8624-1997 Classification on Burning Behaviour for Building Materials
GB 9962 Laminated Glass
GB/T 9963 Tempered Glass
GB/T 13384 General Specifications for Packing of Mechanical and Electrical Product
GB 16776 Structural Silicon Sealants for Building
GB/T 17626.2 Electromagnetic Compatibility (EMC) - Testing and Measurement Techniques - Electrostatic Discharge Immunity Test
GB/T 17626.3 Electromagnetic Compatibility - Testing and Measurement Techniques - Radiated Radio-frequency Electromagnetic Field Immunity Test
GB/T 17626.4 Electromagnetic Compatibility - Testing and Measurement Techniques - Electrical Fast Transient/Burst Immunity Test
GB/T 17626.5 Electromagnetic Compatibility - Testing and Measurement Techniques - Surge Immunity Test
GB/T 17626.6 Electromagnetic Compatibility - Testing and Measurement Techniques - Immunity to Conducted Disturbances Induced by Radio-frequency Fields
GB/T 17626.8 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power Frequency Magnetic Field Immunity Test
GB/T 17626.11 Electromagnetic Compatibility - Testing and Measurement Techniques - Voltage Dips,Short Interruptions and Voltage Variations Immunity Tests
GB 50157 Code for Design of Metro
JC/T 882 Sealants for Joint Glass Curtain Wall
JGJ 102 Technical Code for Glass Curtain Wall Engineering
JGJ 113 Technical Specification for Application of Architectural Glass
3 Terminologies and Definitions
For the purposes of this standard, the following terminologies and definitions apply.
3.1
Urban railway transportation platform screen door system
The continuous barrier installed on edge of platforms of rail transit stations (metro, light rail, etc.) which separates the rail from platform waiting area and is equipped with the sliding door which is corresponding to train door and may be controlled in a multilevel way for the opening/closing; it is also called platform screen door. Such doors include full-height and half-height platform screen doors.
3.2
Emergency escape door
The door for evacuation in case that the train door cannot align to the sliding door.
3.3
Platform end door
The door set at both ends of the platform screen door for getting into and out of the rail zone.
3.4
Driver cab door
The door corresponding to train driver cab door and for getting into and out of the platform.
Foreword i
1 Scope
2 Normative References
3 Terminologies and Definitions
4 Symbols and Abbreviations
5 Requirements
5.1 General Requirements
5.2 Requirements of Door Structure and Mechanical Property
5.3 Monitoring of Platform Screen Door System
5.4 Materials
5.5 Processing and Manufacturing Requirements
6 Test
6.1 Type Test
6.2 End-of-manufacturing Test
7 Packaging, Transportation and Storage
7.1 Packaging
7.2 Transportation
7.3 Storage
Appendix A (Informative) Symbols and Abbreviations
Appendix B (Informative) Test Methods