This standard is developed in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB 12021.3-2010 The minimum allowable value of the energy efficiency and energy efficiency grades for room air conditioners and GB 21455-2013 Minimum allowable values of the energy efficiency and energy efficiency grades for variable speed room air conditioners. In addition to editorial changes, the following main technical changes have been made with respect to GB 12021.3-2010 and GB 21455-2013:
——the scope of this standard is revised (see Clause 1);
——the energy efficiency grade indexes of products are revised (see Clause 4);
——the minimum allowable values of the energy efficiency are revised (see 5.1).
This standard was proposed by the Standardization Administration of the People’s Republic of China and the Department of Resource Conservation and Environmental Protection of the National Development and Reform Commission of the People's Republic of China.
This standard is under the jurisdiction of the Standardization Administration of the People’s Republic of China.
The previous editions of this standard are as follows:
——GB 12021.3-1989, GB 12021.3-2000, GB 12021.3-2004 and GB 12021.3-2010;
——GB 21455-2008 and GB 21455-2013.
Minimum allowable values of the energy efficiency and energy efficiency grades for room air conditioners
1 Scope
This standard specifies the energy efficiency grades, minimum allowable values of the energy efficiency and test methods for room air conditioners.
This standard is applicable to the room air conditioners with air-cooled condensers, fully enclosed electric compressors, rated cooling capacity not greater than 14,000 W and climate type T1, as well as the low ambient temperature air source heat pump air heaters with nominal heating capacity not greater than 14,000W.
This standard is not applicable to portable air conditioners, VRV air conditioning units and air duct air conditioners.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 7725-2004 Room air conditioners
GB/T 35758-2017 Household electrical appliances - Measurement of standby power
JB/T 13573-2018 Low ambient temperature air source heat pump air heaters
3 Terms and definitions
For the purposes of this document, the terms and definitions given in GB/T 7725-2004 and JB/T 13573-2018 as well as the following apply.
3.1
minimum allowable values of energy efficiency for room air conditioners
minimum allowable value of energy efficiency during cooling and heating operation under specified working conditions
3.2
minimum allowable values of energy efficiency for low ambient temperature air source heat pump air heaters
minimum allowable value of the heating seasonal performance factor during heating operation under specified working conditions
3.3
energy consumption in standby mode
energy consumption of the product when powered on but in a non-working state; standby mode is the lowest energy consumption mode of the appliance, in which, the appliance timely monitors the control signals from the remote control device, internal sensor or similar devices that enable it to enter the working state
Note: in this mode, the input power of protection devices with similar functions such as crankcase heater is not included.
4 Energy efficiency grades
4.1 Energy efficiency grades of room air conditioners
4.1.1 The energy efficiency of room air conditioners is classified into five grades, of which, Grade 1 is the highest.
4.1.2 The energy efficiency of heat pump room air conditioners is graded according to the measured annual performance factor (APF) of the product, and APF for each energy efficiency grade shall not be less than that specified in Table 1.
Table 1 Indexes of energy efficiency grades for heat pump room air conditioners
Rated cooling capacity (CC)
W Annual performance factor (APF)
Energy efficiency grade
Grade 1 Grade 2 Grade 3 Grade 4 Grade 5
CC≤4 500 5.00 4.50 4.00 3.50 3.30
4 500
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Energy efficiency grades
5 Technical requirements
6 Test methods
7 Implementation of this standard
Annex A (Normative) Test and calculation methods of seasonal energy efficiency ratio (SEER) and heating seasonal performance factor (HSPF) for room air conditioners
Annex B (Normative) Occurrence time of each temperature in outdoor environment during operation of room air conditioner in cooling and heating seasons
Annex C (Normative) Unsteady-state heating test method
房间空气调节器能效限定值及能效等级
1 范围
本标准规定了房间空气调节器的能效等级、能效限定值和试验方法。
本标准适用于采用空气冷却冷凝器、全封闭电动压缩机,额定制冷量不大于14 000 W、气候类型为T1的房间空气调节器和名义制热量不大于14 000 W的低环境温度空气源热泵热风机。
本标准不适用于移动式空调器、多联式空调机组、风管送风式空调器。
2规范性引用文件
下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
GB/T 7725—2004 房间空气调节器
GB/T 35758—2017家用电器待机功率测量方法
JB/T l3573—2018低环境温度空气源热泵热风机
3术语和定义
GB/T 7725—2004、JB/T l3573—2018界定的以及下列术语和定义适用于本文件。
3.1
房间空气调节器能效限定值 minimum allowable values of energy efficiency for room air-condi-tioners
在规定工况条件下制冷和制热运行时,能源消耗效率的最小允许值。
3.2
低环境温度空气源热泵热风机能效限定值 minimum allowable values of energy efficiency for low ambient temperature air source heat pump air heaters
在规定工况条件下制热运行时,制热季节性能系数的最小允许值。
3.3
待机功率 energy consumption in standby mode
产品接通电源但处于非工作状态的模式下的功率。该模式是器具的最低能耗模式,在待机状态下器具随时监测来自遥控装置、内部传感器或类似装置的可使其进入工作状态的控制信号。
注:该模式下不包含曲轴箱加热器等类似功能保护装置的输入功率。
4能效等级
4.1房间空调器能效等级
4.1.1房间空气调节器能效等级分为5级,其中1级能效等级最高。
4.1.2热泵型房间空气调节器根据产品的实测全年能源消耗效率(APF)对产品能效分级,各能效等级实测全年能源消耗效率(APF)应不小于表1规定。
表1 热泵型房间空气调节器能效等级指标值
额定制冷量(CC)
W 全年能源消耗效率(APF)
能效等级
1级 2级 3级 4级 5级
CC≤4 500 5.00 4.50 4.00 3.50 3.30
4 500