![]() |
中标分类
行业分类
ICS分类
最新标准
|
登录注册 |
您的位置: 标准明细 |
This code is revised by China Mobile Group Design Institute Co., Ltd. jointly with the organizations concerned according to the requirements of Document JIANBIAO [2012] No.5 issued by the Ministry of Housing and Urban-Rural Development- Notice on Printing and Distributing 'the Development and Revision Plan of National Engineering Construction Standards in 2012'. During the process of formulating this code, the code drafting group carries out extensive investigations and studies, carefully summarizes the practical experience, refers to the relevant international and foreign standards, extensively solicits opinions and finalizes this code through review. This code comprises nine chapters and three annexes, with the main technical contents including: General Provisions, Terms and Abbreviations, System Design, Fiber to the Subscriber Unit Communication Facilities, System Configuration Design, Performance Indicators, Installation Requirements, Electrical Protection and Grounding, Fire Prevention, etc. The following technical deviations have been made with respect to the former code: (1) The design requirements of the campus and building generic cabling system and the communication infrastructure engineering are supplemented and perfected on the basis of the contents of GB 50311-2007 Code for Engineering Design of Generic Cabling System. (2) The contents relevant to the application of cabling system in weak system are added. (3) The engineering design requirements for fiber to the subscriber unit communication facilities are added, and the mandatory provisions relevant to the engineering construction of fiber to the subscriber unit communication facilities are newly added. (4) The installation requirements for pipe chase and equipment are enriched. (5) Relevant annexes are added. In this code, the provisions printed in bold type are mandatory ones and must be enforced strictly. The Ministry of Housing and Urban-Rural Development the People's Republic of China is in charge of the administration of this code and the explanation of the mandatory provisions, the Ministry of Industry and Information Technology of the People's Republic of China is responsible for the routine management, and China Mobile Group Design Institute Co., Ltd. is responsible for the explanation of specific technical contents. During the execution process of this code, the relevant opinions and advices, whenever necessary, can be mailed to China Mobile Group Design Institute Co., Ltd. (Address: No.A-16, Danling Street, Haidian District, Beijing, 100080, China). Contents 1 General Provisions 1 2 Terms and Abbreviations 2 2.1 Terms 2 2.2 Abbreviations 6 3 System Design 9 3.1 System Components 9 3.2 System Classification and Composition 12 3.3 Cable Length Division 14 3.4 System Application 18 3.5 Shielded Cabling System 20 3.6 Open Office Cabling System 21 3.7 Industrial Environment Cabling System 22 3.8 Cabling Used in Weak System 26 4 Fibre to the Subscriber Unit Communication Facilities 27 4.1 General Requirements 27 4.2 The Subscriber Access Point Settings 29 4.3 Collocating Principle 31 4.4 Cable and Wiring Equipment Selection 32 4.5 Transmission Indicators 34 5 System Configuration Design 35 5.1 Work Area 35 5.2 Wiring Subsystem 35 5.3 Link Subsystem 37 5.4 Campus Subsystem 38 5.5 Entrance Facilities 38 5.6 Distribution Management System 39 6 Performance Indicators 41 6.1 Cable and Connecting Hardware Performance Indicators 41 6.2 System Performance Indicators 43 7 Installation Requirements 45 7.1 Work Area 45 7.2 Telecommunications Room 46 7.3 Equipment Room 47 7.4 Line Room 49 7.5 Duct and Cable Tray Installation 50 7.6 Cable Laying 52 7.7 Equipment Installation Design 55 8 Electrical Protection and Grounding 57 9 Fire Prevention 59 Annex A System Indicators 60 Annex B Communication Services Supported by 8-bit-module Universal Outlet Terminal 76 Annex C Cable Transmission Performance and Transmission Distance 77 Explanation of Wording in this Code 85 List of Quoted Standard 86 1 General Provisions 1.0.1 This code is formulated with view to standardizing the construction of network integrating voice, data, picture and multimedia services for buildings and campus. 1.0.2 This code is applicable to the engineering design of generic cabling system for constructed, extended and renovated buildings and campus. 1.0.3 The construction of facilities in generic cabling system shall be included in the corresponding planning and design of buildings and campus. The design shall be carried out according to the nature, functions and environmental conditions of engineering project and the short-/long-term subscriber demands, and the construction and maintenance convenience shall be taken into consideration to ensure the quality and safety of generic cabling system engineering and to achieve advanced technology and economic rationality. 1.0.4 Generic cabling system should be planned as a whole and also be designed synchronously together with the wiring of information network system, security technology and protection system and building automation system, etc., and its design shall be reasonably optimized according to the information transmission requirements of these systems. 1.0.5 In the engineering design of generic cabling system, the products selected shall be approved products which are accompanied with acceptance inspection report and meet the relevant technical requirements of the nation. 1.0.6 In addition to this code, the engineering design of generic cabling system shall also comply with those specified in the current relevant standards of the nation. 2 Terms and Abbreviations 2.1 Terms 2.1.1 cabling a system composed of various cables, jumpers, patch cords and connecting hardwares which are capable of supporting the connection of electronic information equipment 2.1.2 campus subsystem a subsystem composed of distributor, backbone cable between buildings, equipment cable, jumper, etc. 2.1.3 telecommunications room a space used for placing telecommunication equipment and distributor for cable termination as well as carrying out cable cross connection 2.1.4 work area isolated area for setting terminal equipment 2.1.5 channel end-to-end transmission channel connecting two application equipment 2.1.6 link a CP link or a permanent link. 2.1.7 permanent link transmission line between telecommunications outlet and floor distributor, which excludes the cables in work area and the equipment cables and jumpers used for connecting floor distributors but may include a CP link 2.1.8 consolidation point (CP) connection point in the horizontal cable route between floor distributor and the telecommunications outlet in work area 2.1.9 CP link permanent link, including the connecting hardwares at both ends, between floor distributor and consolidation point (CP) 2.1.10 campus distributor distributor used for terminating the campus backbone cable 2.1.11 building distributor distributor used for terminating the building backbone cable or campus backbone cable 2.1.12 floor distributor distributor used for terminating the horizontal cable and the cables in other cabling subsystems 2.1.13 building entrance facility connecting hardware which provides mechanical and electrical characteristics meeting the relevant codes and leads the external network cable into the building 2.1.14 connecting hardware a hardware or a group of hardwares used for connecting electric cable pairs and optical cables and fibres 2.1.15 optical fibre adapter hardware realizing the optical connection of optical fibre connector 2.1.16 campus backbone cable connecting cable between campus distributor and building distributor in a campus 2.1.17 building backbone cable connecting cable between building entrance facility and building distributor, between building distributor and floor distributor, and between floor distributors in a building 2.1.18 horizontal cable connecting cable between floor distributor and telecommunications outlet 2.1.19 CP cable connecting cable between consolidation point (CP) and the telecommunications outlet in work area 2.1.20 telecommunications outlet (TO) telecommunications outlet module for terminating a cable 2.1.21 equipment cable connecting cable between communication equipment and distributor 2.1.22 patch cord/jumper the cable pair without or with connecting hardware and the optical fibre with connecting hardware, which are used for the connection between distributors 2.1.23 cable a general term of electric cable and optical cable 2.1.24 optical cable cable composed of single-core or multi-core optical fibres 2.1.25 pair a pair which is composed of two mutually insulated conductors by pair twisting and generally is a balanced pair 2.1.26 balanced cable symmetrical cable composed of one or more metal conductor pairs 2.1.27 screened balanced cable balanced cable with a general screen or with a screen on each pair 2.1.28 unscreened balanced cable balanced cable without any screen 2.1.29 patch cord flexible cable with connecting hardware at one end or both ends 2.1.30 multi-user telecom-munication outlet combined device of several telecommunications outlet modules in the work area 2.1.31 the wiring zone the wiring zone composed of the subscriber units of single building or several buildings according to the type, scale and subscriber unit density of buildings 2.1.32 the wiring pipeline network pipeline network composed of the external line inlet pipes of building and the shafts, pipes and cable trays, etc. in a building 2.1.33 the subscriber access point a common access position for telecommunication service of multiple telecommunication service operators, and also the engineering interface between telecommunication service operators and building developer 2.1.34 subscriber unit the subscriber area which occupies certain space in building, has variable users or services and needs to be directly interconnected and intercommunicated with the public telecommunication network 2.1.35 fiber to the subscriber unit communication facilities the underground communication pipeline within the planned land boundary line of building and the pipe chase, communication optical cable, optical distributor, subscriber unit information distribution box, reserved equipment room and other equipment installation spaces in building in a fiber to the subscriber unit engineering 2.1.36 wiring optical cable intercommunication optical cable between the subscriber access point and the aggregation distributor of park or campus optical cable or between the subscriber access point and the manhole (handhole) intercommunicating with public communication pipeline within the planned land boundary line of building 2.1.37 subscriber optical cable connecting optical cable between the distributor at subscriber access point and the subscriber unit information distribution box in a building 2.1.38 indoor cable connecting cable between the subscriber unit information distribution box and the telecommunications outlet module in subscriber area 2.1.39 information distribution box distribution box which is installed in subscriber unit area and is used for completing information intercommunication and communication service access 2.1.40 cable tray a general term of cable ladder, tray and trunking 2.2 Abbreviations ACR-F (Attenuation to Crosstalk Ratio at the Far-end) ACR-N (Attenuation to Crosstalk Ratio at the Near-end) BD (Building Distributor) CD (Campus Distributor) CP (Consolidation Point) d.c. (Direct Current loop resistance) ELTCTL (Equal Level TCTL) FD (Floor Distributor) FEXT [Far End Crosstalk Attenuation (loss)] ID (Intermediate Distributor) IEC (International Electrotechnical Commission) IEEE (the Institute of Electrical and Electronics Engineers) IL (Insertion Loss) IP (Internet Protocol) ISDN (Integrated Services Digital Network) ISO (International Organization for Standardization) MUTO (Multi-User Telecom-munications Outlet) MPO (Multi-fiber Push On) NI (Network Interface) NEXT [Near End Crosstalk Attenuation (loss)] OF (Optical Fibre) POE (Power Over Ethernet) PS NEXT [Power Sum Near End Crosstalk Attenuation (loss)] PS AACR-F (Power Sum Attenuation to Alien Crosstalk Ratio at the Far-end) PS AACR-Favg (Average Power Sum Attenuation to Alien Crosstalk Ratio at the Far-end) PS ACR-F (Power Sum Attenuation to Crosstalk Ratio at the Far-end) PS ACR-N (Power Sum Attenuation to Crosstalk Ratio at the Near-end) PS ANEXT [Power Sum Alien Near-End Crosstalk (loss)] PS ANEXTavg [Average Power Sum Alien Near-End Crosstalk (loss)] PS FEXT [Power Sum Far-end Crosstalk (loss)] RL (Return Loss) SC [Subscriber Connector (optical fibre connector)] SW (Switch) SFF (Small Form Factor connector) TCL (Transverse Conversion Loss) TCTL (Transverse Conversion Transfer Loss) TE (Terminal Equipment) TO (Telecommunications Outlet) TIA (Telecommunications Industry Association) UL (Underwriters Laboratories) Vr.m.s (Vroot.mean.square) 3 System Design 3.1 System Components 3.1.1 Generic cabling system shall be of open network topology and shall be capable of supporting the information transmission applications of such services as voice, data, picture and multimedia. 3.1.2 The components of generic cabling system shall meet the following requirements: 1 The basic components of generic cabling system shall include campus subsystem, link subsystem and wiring subsystem (Figure 3.1.2-1). In wiring subsystem, consolidation point (CP) may be or not be set. Figure 3.1.2-1 Basic Components of Generic Cabling System 2 In all subsystems of generic cabling system, direct route may be established between floor distributors (FDs) in a building and between building distributors (BDs) of different buildings [Figure 3.1.2-2(a)]. The telecommunications outlet (TO) in work area may be directly connected to the building distributor (BD) without passing through the floor distributor (FD) and the floor distributor may also be directly interconnected with the campus distributor (CD) without passing through the building distributor (BD) [Figure 3.1.2-2(b)]. 3 When the building entrance facility of generic cabling system is connected with the external network and the incoming cable of other buildings, they shall be interconnected via cable and BD/CD (Figure 3.1.2-3). For the building designed with an equipment room, the corresponding floor distributor (FD) of this equipment room may be installed at the same site as the building distributor/campus distributor (BD/CD) in this equipment room as well as the building entrance facility. Figure 3.1.2-2 Components of Subsystems in Generic Cabling System Figure 3.1.2-3 Components of Incoming Part in Generic Cabling System 4 In typical application of generic cabling system, the channel of wiring subsystem shall be composed of 4-pair balanced cable and cable connecting hardware, and the channel of link subsystem and campus subsystem shall be composed of optical cable and optical cable connecting hardware. Thereinto, interconnection or cross connection mode may be adopted between the wiring module at building distributor (FD) and campus distributor (CD) and the network equipment, and the optical fibre wiring module at building distributor (BD) may be only interconnected with optical fibre (Figure 3.1.2-4). Figure 3.1.2-4 Typical Connections and Components in Application of Generic Cabling System 3.1.3 The engineering design of generic cabling system shall meet the following requirements: 1 An independent area where terminal equipment (TE) will be set should be classified as a work area. The work area shall include telecommunications outlet (TO) module, connecting cable at terminal equipment, and adapter. 2 Wiring subsystem shall be composed of the telecommunications outlet module in work area, the horizontal cable between telecommunications outlet module and the distributor (FD) in telecommunications room, the distributor in telecommunications room, and equipment cable and jumper, etc. 3 Link subsystem shall be composed of the backbone cable between equipment room and telecommunications room and the building distributor (BD), equipment cable and jumper installed in equipment room. 4 Campus subsystem shall be composed of the connecting backbone cable among multiple buildings, the campus distributor (CD), equipment cable and jumper. 5 Equipment room shall be arranged at proper place in each building and used for wiring management, network management and information exchange. In the equipment room of generic cabling system, the building distributor, campus distributor, Ethernet switch, telephone switch and computer network facilities should be installed, and the building entrance facility may also be installed. 6 Line room shall be the entrance position for pipelines of external information communication network for buildings and may also be used as the installation site of building entrance facility. 7 As for management, the distributor, cable, telecommunications outlet module and other facilities in work area, telecommunications room, equipment room, line room and cabling route environment shall be marked, recorded and managed in certain mode. 3.1.4 Connection between generic cabling system and external wiring network shall comply with corresponding interface requirements. 3.2 System Classification and Composition 3.2.1 The classification and category division of cable wiring system in generic cabling system shall be in accordance with those specified in Table 3.2.1. 1 General Provisions 2 Terms and Abbreviations 2.1 Terms 2.2 Abbreviations 3 System Design 3.1 System Components 3.2 System Classification and Composition 3.3 Cable Length Division 3.4 System Application 3.5 Shielded Cabling System 3.6 Open Office Cabling System 3.7 Industrial Environment Cabling System 3.8 Cabling Used in Weak System 4 Fibre to the Subscriber Unit Communication Facilities 4.1 General Requirements 4.2 The Subscriber Access Point Settings 4.3 Collocating Principle 4.4 Cable and Wiring Equipment Selection 4.5 Transmission Indicators 5 System Configuration Design 5.1 Work Area 5.2 Wiring Subsystem 5.3 Link Subsystem 5.4 Campus Subsystem 5.5 Entrance Facilities 5.6 Distribution Management System 6 Performance Indicators 6.1 Cable and Connecting Hardware Performance Indicators 6.2 System Performance Indicators 7 Installation Requirements 7.1 Work Area 7.2 Telecommunications Room 7.3 Equipment Room 7.4 Line Room 7.5 Duct and Cable Tray Installation 7.6 Cable Laying 7.7 Equipment Installation Design 8 Electrical Protection and Grounding 9 Fire Prevention Annex A System Indicators Annex B Communication Services Supported by 8-bit-module Universal Outlet Terminal Annex C Cable Transmission Performance and Transmission Distance Explanation of Wording in this Code List of Quoted Standard 1 总 则 1.0.1 为了规范建筑与建筑群的语音、数据、图像及多媒体业务综合网络建设,制定本规范。 1.0.2本规范适用于新建、扩建、改建建筑与建筑群综合布线系统工程设计。 1.0.3综合布线系统设施的建设,应纳入建筑与建筑群相应的规划设计之中,根据工程项目的性质、功能、环境条件和近、远期用户需求进行设计,应考虑施工和维护方便,确保综合布线系统工程的质量和安全,做到技术先进、经济合理。 1.0.4综合布线系统宜与信息网络系统、安全技术防范系统、建筑设备监控系统等的配线作统筹规划,同步设计,并应按照各系统对信息的传输要求,做到合理优化设计。 1.0.5 综合布线系统工程设计中应选用出具合格检验报告、符合国家有关技术要求的定型产品。 1.0.6综合布线系统的工程设计除应符合本规范外,尚应符合国家现行有关标准的规定。 2术语和缩略语 2.1 术 语 2.1.1布线 cabling 能够支持电子信息设备相连的各种缆线、跳线、接插软线和连接器件组成的系统。 2.1.2建筑群子系统 campus subsystem 建筑群子系统由配线设备、建筑物之间的干线缆线、设备缆线、跳线等组成。 2.1.3 电信间telecommunications room 放置电信设备、缆线终接的配线设备,并进行缆线交接的一个空间。 2.1.4工作区 work area 需要设置终端设备的独立区域。 2.1.5信道 channel 连接两个应用设备的端到端的传输通道。 2.1.6链路link 一个CP链路或是一个永久链路。 2.1.7永久链路permanent link 信息点与楼层配线设备之间的传输线路。它不包括工作区缆线和连接楼层配线设备的设备缆线、跳线,但可以包括一个CP链路。 2.1.8集合点 consolidation point(CP) 楼层配线设备与工作区信息点之间水平缆线路由中的连接点。 2.1.9 CP链路 CP link 楼层配线设备与集合点(CP)之间,包括两端的连接器件在内的永久性的链路。 2.1.10建筑群配线设备 campus distributor 终接建筑群主干缆线的配线设备。 2.1.11建筑物配线设备 building distributor 为建筑物主干缆线或建筑群主干缆线终接的配线设备。 2.1.12楼层配线设备 floor distributor 终接水平缆线和其他布线子系统缆线的配线设备。 2.1.13 入口设施 building entrance facility 提供符合相关规范的机械与电气特性的连接器件,使得外部网络缆线引入建筑物内。 2.1.14 连接器件 connecting hardware 用于连接电缆线对和光缆光纤的一个器件或一组器件。 2.1.15光纤适配器 optical fibre adapter 将光纤连接器实现光学连接的器件。 2.1.16建筑群主干缆线 campus backbone cable 用于在建筑群内连接建筑群配线设备与建筑物配线设备的缆线。 2.1.17建筑物主干缆线 building backbone cable 入口设施至建筑物配线设备、建筑物配线设备至楼层配线设备、建筑物内楼层配线设备之间相连接的缆线。 2.1.18水平缆线horizontal cable 楼层配线设备至信息点之间的连接缆线。 2.1.19 CP缆线 CP cable 连接集合点(CP)至工作区信息点的缆线。 2.1.20信息点(TO)telecommunications outlet 缆线终接的信息插座模块。 2.1.21 设备缆线 equipment cable 通信设备连接到配线设备的缆线。 2.1.22跳线patch cord/jumper 不带连接器件或带连接器件的电缆线对和带连接器件的光纤,用于配线设备之间进行连接。 2.1.23缆线 cable 电缆和光缆的统称。 2.1.24光缆 optical cable 由单芯或多芯光纤构成的缆线。 2.1.25线对pair 由两个相互绝缘的导体对绞组成,通常是一个对绞线对。 2.1.26对绞电缆 balanced cable 由一个或多个金属导体线对组成的对称电缆。 2.1.27 屏蔽对绞电缆 screened balanced cable 含有总屏蔽层和/或每线对屏蔽层的对绞电缆。 2.1.28非屏蔽对绞电缆 unscreened balanced cable 不带有任何屏蔽物的对绞电缆。 2.1.29接插软线patch cord 一端或两端带有连接器件的软电缆。 2.1.30 多用户信息插座 multi-user telecom-munication outlet 工作区内若干信息插座模块的组合装置。 2.1.31配线区the wiring zone 根据建筑物的类型、规模、用户单元的密度,以单栋或若干栋建筑物的用户单元组成的配线区域。 2.1.32 配线管网the wiring pipeline network 由建筑物外线引入管、建筑物内的竖井、管、桥架等组成的管网。 2.1.33 用户接入点the subscriber access Doint 多家电信业务经营者的电信业务共同接入的部位,是电信业务经营者与建筑建设方的工程界面。 2.1.34 用户单元 subscriber unit 建筑物内占有一定空间、使用者或使用业务会发生变化的、需要直接与公用电信网互联互通的用户区域。 2.1.35 光纤到用户单元通信设施 fiber to the subscriber unit communication facilities 光纤到用户单元工程中,建筑规划用地红线内地下通信管道、建筑内管槽及通信光缆、光配线设备、用户单元信息配线箱及预留的设备间等设备安装空间。 2.1.36配线光缆 wiring optical cable 用户接入点至园区或建筑群光缆的汇聚配线设备之间,或用户接入点至建筑规划用地红线范围内与公用通信管道互通的人(手)孔之间的互通光缆。 2.1.37 用户光缆 subscriber optical cable 用户接入点配线设备至建筑物内用户单元信息配线箱之间相连接的光缆。 2.1.38户内缆线 indoor cable 用户单元信息配线箱至用户区域内信息插座模块之间相连接的缆线。 2.1.39信息配线箱 information distribution box 安装于用户单元区域内的完成信息互通与通信业务接入的配线箱体。 2.1.40桥架 cable tray 梯架、托盘及槽盒的统称。 2.2 缩 略 语 ACR-F(Attenuation to Crosstalk Ratio at the Far-end) 衰减远端串音比 ACR-N(Attenuation to Crosstalk Ratio at the Near-end) 衰减近端串音比 BD(Building Distributor) 建筑物配线设备 CD(Campus Distributor) 建筑群配线设备 CP(Consolidation Point) 集合点 d.c.(Direct Current loop resistance) 直流环路电阻 ELTCTL(Equal Level TCTL) 两端等效横向转换损耗 FD(Floor Distributor) 楼层配线设备 FEXT[Far End Crosstalk Attenuation(loss)] 远端串音 ID(Intermediate Distributor) 中间配线设备 IEC(International Electrotechnical Commission) 国际电工技术委员会 IEEE(the Institute of Electrical and Electronics Engineers) 美国电气及电子工程师学会 IL(Insertion Loss) 插入损耗 IP(Internet Protocol) 因特网协议 ISDN(Integrated Services Digital Network) 综合业务数字网 ISO(International Organization for Standardization) 国际标准化组织 MUTO(Multi-User Telecom-munications Outlet) 多用户信息插座 MPO(Multi-fiber Push On) 多芯推进锁闭光纤连接器件 NI(Network Interface) 网络接VI NEXT[Near End Crosstalk Attenuation(loss)] 近端串音 OF(Optical Fibre) 光纤 POE(Power Over Ethernet) 以太网供电 PS NEXT[Power Sum Near End Crosstalk Attenuation(loss)] 近端串音功率和 PS AACR-F(Power Sum Attenuation to Allen Crosstalk Ra-tio at the Far-end) 外部远端串音比功率和 PS AACR-Favg(Average Power Sum Attenuation to Alien Crosstalk Ratio at the Far-end) 外部远端串音比功率和平均值 PS ACR-F(Power Sum Attenuation to Crosstalk Ratio at the Far-end) 衰减远端串音比功率和 PS ACR-N(Power Sum Attenuation to Crosstalk Ratio at the Near-end) 衰减近端串音比功率和 PS ANEXT[Power Sum Alien Near-End Crosstalk(loss)] 外部近端串音功率和 PS ANEXTavg[Average Power Sum Alien Near-EndCrosstalk(loss)] 外部近端串音功率和平均值 PS FEXT[Power Sum Far end Crosstalk(loss)] 远端串音功率和 RL(Return Loss) 回波损耗 SC[Subscriber Connector(optical fibre connector)] 用户连接器件(光纤活动连接器件) SW(Switch) 交换机 SFF(Small Form Factor connector) 小型光纤连接器件 TCL(Transverse Conversion Loss) 横向转换损耗 TCTL(Transverse Conversion Transfer Loss) 横向转换转移损耗 TE(Terminal Equipment) 终端设备 TO(Telecommunications Outlet) 信息点 TIA(Telecommunications Industry Association) 美国电信工业协会 UL(Underwriters Laboratories) 美国保险商实验所安全标准 Vr.m.s(Vroot.mean.square) 电压有效值 3 系统设计 3.1系统构成 3.1.1 综合布线系统应为开放式网络拓扑结构,应能支持语音、数据、图像、多媒体等业务信息传递的应用。 3.1.2综合布线系统的构成应符合下列规定: 1 综合布线系统的基本构成应包括建筑群子系统、干线子系统和配线子系统(图3.1.2-1)。配线子系统中可以设置集合点(CP),也可不设置集合点。 建筑群子系统 干线子系统 配线子系统 设备缆线 综合布线系统 图3.1.2-1 综合布线系统基本构成 2综合布线各子系统中,建筑物内楼层配线设备(FD)之间、不同建筑物的建筑物配线设备(BD)之间可建立直达路由[图3.1.2-2(a)]。工作区信息插座(TO)可不经过楼层配线设备(FD)直接连接至建筑物配线设备(BD),楼层配线设备(FD)也可不经过建筑物配线设备(BD)直接与建筑群配线设备(CD)互连[图3.1.2-2(b)]。 3综合布线系统入口设施连接外部网络和其他建筑物的引入缆线,应通过缆线和BD或CD进行互连(图3.1.2-3)。对设置了设备间的建筑物,设备间所在楼层配线设备(FD)可以和设备间中的建筑物配线设备或建筑群配线设备(BD/CD)及入口设施安装在同一场地。 建筑群子系统 干线子系统 配线子系统 建筑群子系统 干线子系统 配线子系统 图3.1.2-2综合布线子系统构成 外部网络 其他建筑物缆线 入口设施 图3.1.2 3综合布线系统引入部分构成 4综合布线系统典型应用中,配线子系统信道应由4对对绞电缆和电缆连接器件构成,干线子系统信道和建筑群子系统信道应由光缆和光连接器件组成。其中建筑物配线设备(FD)和建筑群配线设备(CD)处的配线模块和网络设备之间可采用互连或交叉的连接方式,建筑物配线设备(BD)处的光纤配线模块可仅对光纤进行互连(图3.1.2-4)。 设备 光纤信道 对绞电缆信道 图3.1.2-4 综合布线系统应用典型连接与组成 3.1.3综合布线系统工程设计应符合下列规定: 1 一个独立的需要设置终端设备(TE)的区域宜划分为一个工作区。工作区应包括信息插座模块(TO)、终端设备处的连接缆线及适配器。 2 配线子系统应由工作区内的信息插座模块、信息插座模块至电信间配线设备(FD)的水平缆线、电信间的配线设备及设备缆线和跳线等组成。 3干线子系统应由设备间至电信间的主干缆线、安装在设备间的建筑物配线设备(BD)及设备缆线和跳线组成。 4 建筑群子系统应由连接多个建筑物之间的主干缆线、建筑群配线设备(CD)及设备缆线和跳线组成。 5设备间应为在每栋建筑物的适当地点进行配线管理、网络管理和信息交换的场地。综合布线系统设备间宜安装建筑物配线设备、建筑群配线设备、以太网交换机、电话交换机、计算机网络设备。入口设施也可安装在设备间。 6 进线间应为建筑物外部信息通信网络管线的入口部位,并可作为入口设施的安装场地。 7管理应对工作区、电信间、设备间、进线间、布线路径环境中的配线设备、缆线、信息插座模块等设施按一定的模式进行标识、记录和管理。 3.1.4综合布线系统与外部配线网连接时,应遵循相应的接口要求。 3.2系统分级与组成 3.2.1 综合布线电缆布线系统的分级与类别划分应符合表 3.2.1的规定。 表3.2.1 电缆布线系统的分级与类别 系统 系统产品类别 支持最高带宽(Hz) 支持应用器件 分级 电缆 连接硬件 A — 100K — — B — 1M — — C 3类(大对数) 16M 3类 3类 D 5类(屏蔽和非屏蔽) 100M 5类 5类 E 6类(屏蔽和非屏蔽) 250M 6类 6类 EA 6A类(屏蔽和非屏蔽) 500M 6A类 6A类 F 7类(屏蔽) 600M 7类 7类 FA 7A类(屏蔽) 1000M 7A类 7A类 注:5、6、6A、7、7A类布线系统应能支持向下兼容的应用。 3.2.2 布线系统信道应由长度不大于90m的水平缆线、10m的跳线和设备缆线及最多4个连接器件组成,永久链路则应由长度不大于90m水平缆线及最多3个连接器件组成(图3.2.2)。 信息 永久链路 CP链路 工作区 设备缆线 设备缆线 跳线 水平缆线 CP缆线 设备 图3.2.2 布线系统信道、永久链路、CP链路构成 3.2.3光纤信道应分为OF-300、OF-500和OF-2000三个等级,各等级光纤信道应支持的应用长度不应小于300m、500m及2000m。 3.2.4光纤信道构成方式应符合下列规定: 1 水平光缆和主干光缆可在楼层电信间的光配线设备(FD)处经光纤跳线连接构成信道(图3.2.4-1)。 光信道 主干光缆 水平光缆 设备光缆 CP光缆 工作区 设备光缆 设备 光跳线 光跳线 水平光缆 图3.2.4-1光纤信道构成1 2水平光缆和主干光缆可在楼层电信间处经接续(熔接或机械连接)互通构成光纤信道(图3.2.4-2)。 光信道 主干光缆 水平光缆 设备光缆 CP光缆 工作区 设备光缆 设备 光跳线 光纤接续点 水平光缆 图3.2.4-2光纤信道构成2 3 电信间可只作为主干光缆或水平光缆的路径场所(图3.2.4 3)。 3.2.5 当工作区用户终端设备或某区域网络设备需直接与公用通信网进行互通时,宜将光缆从工作区直接布放至电信业务经营者提供的入口设施处的光配线设备。 光信道 主干或水平光缆 设备光缆 电信间 CP光缆 工作区 设备光缆 设备 光跳线 主干或水平光缆 图3.2.4-3光纤信道构成3 3.3缆线长度划分 3.3.1 主干缆线组成的信道出现4个连接器件时,缆线的长度不应小于15m。 3.3.2配线子系统信道的最大长度不应大于100m(图3.3.2),长度应符合表3.3.2的规定。 信道 设备缆线 跳线 水平缆线 CP缆线 工作区 设备缆线 设备 图3.3.2配线子系统缆线划分 表3.3.2配线子系统缆线长度 连接模型 最小长度(m) 最大长度(m) FD-CP 15 85 CP-TO 5 FD-TO(无CP) 15 90 工作区设备缆线① 2 5 跳线 2 FD设备缆线② 2 5 设备缆线与跳线总长度 10 注:①此处没有设置跳线时,设备缆线的长度不应小于1m。 ②此处不采用交叉连接时,设备缆线的长度不应小于1m。 3.3.3缆线长度计算应符合下列规定: 1 配线子系统(水平)信道长度应符合下列规定: 1)配线子系统信道应由永久链路的水平缆线和设备缆线组成,可包括跳线和CP缆线(图3.3.3-1)。 设备 设备缆线 永久链路 信道最长100m (a)方式 设备 设备缆线 跳线 永久链路 信道最长100m (b)方式2 设备 设备缆线 CP缆线 永久链路 信道最长100m (c)方式3 设备 设备缆线 CP缆线 设备缆线 跳线 永久链路 信道最长100m (d)方式4 图3.3.3-1配线子系统信道连接方式 2)配线子系统信道长度计算方法应符合表3.3.3-1规定。 表3.3.3-1 配线子系统信道长度计算 连接模型 对应图号 等 级 D E或EA F或FA FD互连—TO 图3.3.3-1 H=109-FX H=107-3-FX H=107-2-FX FD交叉—TO 图3.3.3-2 H=107-FX H=106-3-FX H=106-3-FX FD互连—CP—O 图3.3.3-3 H=107-FX-CY H=106-3-FX-CY H=106-3-FX-CY FD交叉—CP—TO 图3.3.3-4 H=105-FX-CY H=105-3-FX-CY H=105-3-FX-CY 注:1计算公式中:H为水平缆线的最大长度(m),F为楼层配线设备(FD)缆线和跳线及工作区设备缆线总长度(m),C为集合点(CP)缆线的长度(m),X为设备缆线和跳线的插入损耗(dB/m)与水平缆线的插入损耗(dB/m)之比,Y为集合点(CP)缆线的插入损耗(dB/m)与水平缆线的插入损耗(dB/m)之比,2和3为余量,以适应插入损耗值的偏离。 2水平电缆的应用长度会受到工作环境温度的影响。当工作环境温度超过20℃时,屏蔽电缆长度按每摄氏度减少0.2%计算,对非屏蔽电缆长度则按每摄氏度减少0.4%(20℃~40℃)和每摄氏度减少0.6%(>40℃~60℃)计算。 2干线子系统信道长度应符合下列规定: 1)干线子系统信道应包括主干缆线、跳线和设备缆线(图3.3.3-2)。 设备 设备缆线 CD或BD BD或FD 设备缆线 设备 跳线 主干缆线 信道 图3.3.3 2干线子系统信道连接方式 2)干线子系统信道长度计算方法应符合表3.3.3-2的规定。 3.4系统应用 3.4.1 综合布线系统工程的产品类别及链路、信道等级的确定应综合考虑建筑物的性质、功能、应用网络和业务对传输带宽及缆线长度的要求、业务终端的类型、业务的需求及发展、性能价格、现场安装条件等因素,并应符合表3.4.1的规定。 表3.4.1布线系统等级与类别的选用 业务 配线子系统 干线子系统 建筑群子系统 种类 等级 类别 等级 类别 等级 类别 语音 D/E 5/6(4对) C/D 3/5(大对数) C 3(室外大对数) 数据 电缆 D、E、EA、F、FA 5、6、6A、7、7A(4对) E、EA、F、FA 6、6A、7、7A(4对) — — 光纤 OF-300OF-500OF-2000 OM1、OM2、OM3、OM4多模光缆;OS1、OS2单模光缆及相应等级连接器件 OF-300OF-500OF-2000 OM1、OM2、OM3、OM4多模光缆;OS1、OS2单模光缆及相应等级连接器件 OF-300OF-500OF-2000 OS1、OS2单模光缆及相应等级连接器件 其他应用① 可采用5/6/6A类4对对绞电缆和OM1/OM2/OM3/OM4多模、OS1/OS2单模光缆及相应等级连接器件 注:①为建筑物其他弱电子系统采用网络端口传送数字信息时的应用。 表3.3.3-2 干线子系统信道长度计算 类别 等 级 A B C D E EA F FA 5 2000 B=250-FX B=170-FX B=105-FX — — — — 6 2000 B=260-FX B=185-FX B=111-FX B=105-3-FX — — — 6A 2000 B=260-FX B=189-FX B=114-FX B=108-3-FX B=105-3-FX — — 7 2000 B=260-FX B=190-FX B=115-FX B=109-3-FX B=107-3-FX B=105-3-FX — 7A 2000 B=260-FX B=192-FX B=117-FX B=111-3-FX B=105-3-FX B=105-3-FX B=105-3FX 注:1 计算公式中:B为主干缆线的长度(m),F为设备缆线与跳线总长度(m),X为设备缆线的插入损耗(dB/m)与主干缆线的插入损耗(dB/m)之比,3为余量,以适应插入损耗值的偏离。 2 当信道包含的连接点数与图3.3.3-2所示不同,当连接点大于或小于6个时,线缆敷设长度应减少或增加。减少与增加缆线长度的原则为:5类电缆,按每个连接点对应2m计;6类、6A类和7类电缆,按每个连接点对应1m计。而且宜对NEXT、RL和ACR-F予以验证。 3 主干电缆(连接FD~BD、BD~BD、FD~CD、BD~CD)的应用长度会受到工作环境温度的影响。当工作环境的温度超过20℃时,屏蔽电缆长度按每摄氏度减少0.2%计算,对非屏蔽电缆长度则按每摄氏度减少0.4%(20℃~40℃)和每摄氏度减少0.6%(>40℃~60℃)计算。 3.4.2 同一布线信道及链路的缆线、跳线和连接器件应保持系统等级与阻抗的一致性。 3.4.3 综合布线系统光纤信道应采用标称波长为850nm和1300nm的多模光纤(OM1、OM2、OM3、OM4),标称波长为1310nm和1550nm(OS1),1310nm、1383nm和1550nm(OS2)的单模光纤。 3.4.4单模和多模光缆的选用应符合网络的构成方式、业务的互联方式、以太网交换机端口类型及网络规定的光纤应用传输距离。在楼内宜采用多模光缆,超过多模光纤支持的应用长度或需直接与电信业务经营者通信设施相连时应采用单模光缆。 3.4.5 配线设备之间互连的跳线宜选用产业化制造的产品,跳线的类别应符合综合布线系统的等级要求。在应用电话业务时宜选用双芯对绞电缆。 3.4.6工作区信息点为电端口时应采用8位模块通用插座,光端口应采用SC或LC光纤连接器件及适配器。 3.4.7 FD、BD、CD配线设备应根据支持的应用业务、布线的等级、产品的性能指标选用,并应符合下列规定: 1 应用于数据业务时,电缆配线模块应采用8位模块通用插座。 2应用于语音业务时,FD干线侧及BD、CD处配线模块应选用卡接式配线模块(多对、25对卡接式模块及回线型卡接模块),FD水平侧配线模块应选用8位模块通用插座。 3光纤配线模块应采用单工或双工的SC或LC光纤连接器件及适配器。 4主干光缆的光纤容量较大时,可采用预端接光纤连接器件(MPO)互通。 3.4.8 CP集合点安装的连接器件应选用卡接式配线模块或8位模块通用插座或各类光纤连接器件和适配器。 3.4.9 综合布线系统产品的选用应考虑缆线与器件的类型、规格、尺寸对安装设计与施工造成的影响。 3.5屏蔽布线系统 3.5.1 屏蔽布线系统的选用应符合下列规定: 1 当综合布线区域内存在的电磁干扰场强高于3V/m时,宜采用屏蔽布线系统。 2用户对电磁兼容性有电磁干扰和防信息泄漏等较高的要求时,或有网络安全保密的需要时,宜采用屏蔽布线系统。 3安装现场条件无法满足对绞电缆的间距要求时,宜采用屏蔽布线系统。 4 当布线环境温度影响到非屏蔽布线系统的传输距离时,宜采用屏蔽布线系统。 3.5.2屏蔽布线系统应选用相互适应的屏蔽电缆和连接器件,采用的电缆、连接器件、跳线、设备电缆都应是屏蔽的,并应保持信道屏蔽层的连续性与导通性。 3.6开放型办公室布线系统 3.6.1 对于办公楼、综合楼等商用建筑物或公共区域大开间的场地,宜按开放型办公室综合布线系统要求进行设计。 3.6.2采用多用户信息插座(MUTO)时,每一个多用户插座宜能支持12个工作区所需的8位模块通用插座,并宜包括备用量。 3.6.3各段电缆长度应符合表3.6.3的规定,其中,C、W取值应按下列公式进行计算: C=(102-H)/(1+D) (3.6.3-1) W=C-T (3.6.3-2) 式中:C——工作区设备电缆、电信间跳线及设备电缆的总长度; H——水平电缆的长度,(H+C)≤100m; T——电信间内跳线和设备电缆长度; W——工作区设备电缆的长度; D——调整系数,对24号线规D取为0.2,对26号线规D取为0.5。 表3.6.3各段电缆长度限值 电缆总长度 24号线规(AWG) 26号线规(AWG) H(m) W(m) C(m) W(m) C(m) 90 5 10 4 8 85 9 14 7 11 80 13 18 11 15 75 17 22 14 18 70 22 27 17 21 3.6.4 采用集合点(CP)时,集合点配线设备与FD之间水平缆线的长度不应小于15m,并应符合下列规定: 1集合点配线设备容量宜满足12个工作区信息点的需求。 2 同一个水平电缆路由中不应超过一个集合点(CP)。 3 从集合点引出的CP电缆应终接于工作区的8位模块通用插座或多用户信息插座。 4从集合点引出的CP光缆应终接于工作区的光纤连接器。 3.6.5 多用户信息插座和集合点的配线箱体应安装于墙体或柱子等建筑物固定的永久位置。 3.7工业环境布线系统 3.7.1 在高温、潮湿、电磁干扰、撞击、振动、腐蚀气体、灰尘等恶劣环境中应采用工业环境布线系统,并应支持语音、数据、图像、视频、控制等信息的传递。 3.7.2工业环境布线系统设置应符合下列规定: 1 工业级连接器件应使用于工业环境中的生产区、办公区或控制室与生产区之间的交界场所,也可应用于室外环境。 2 在工业设备较为集中的区域应设置现场配线设备。 3 工业环境中的配线设备应根据环境条件确定防护等级。 3.7.3工业环境布线系统应由建筑群子系统、干线子系统、配线子系统、中间配线子系统组成(图3.7.3)。 建筑群子系统 干线子系统 配线子系统 中间配线子系统 设备缆线 操作区 综合布线系统 图3.7.3工业环境布线系统架构 3.7.4 工业环境布线系统的各级配线设备之间宜设置备份或互通的路由,并应符合下列规定: 1 建筑群CD与每一个建筑物BD之间应设置双路由,其中1条应为备份路由。 2 不同的建筑物BD与BD、本建筑BD与另一栋建筑FD之间可设置互通的路由。 3本建筑物不同楼层FD与FD、本楼层FD与另一楼层ID之间可设置互通路由。 4 楼层内ID与ID、ID与非本区域的TO之间可设置互通的路由。 3.7.5 布线信道中含有中间配线子系统时,网络设备与ID配线模块之间应采用交叉或互连的连接方式。 3.7.6 在工程应用中,工业环境的布线系统应由光纤信道和对绞电缆信道构成(图3.7.6),并应符合下列规定: 设备 光纤信道 对绞电缆信道 图3.7.6 工业环境布线系统光纤信道与电缆信遭构成 1 中间配线设备ID至工作区TO信息点之间对绞电缆信道应采用符合D、E、EA、F、FA等级的5、6、6A、7、7A布线产品。布线等级不应低于D级。 2光纤信道可分为塑料光纤信道OF-25、OF-50、OF-100、OF-200,石英多模光纤信道OF-100、OF-300、OF-500及单模光纤信道OF-2000、OF-5000、OF-10000的信道等级。 3.7.7 中间配线设备ID处跳线与设备缆线的长度应符合表3.7.7的规定。 表3.7.7设备缆线与跳线长度 连接模型 最小长度(m) 最大长度(m) ID-TO 15 90 工作区设备缆线 1 5 配线区跳线 2 — 配线区设备缆线① 2 5 跳线、设备缆线总长度 — 10 注:①此处没有没置跳线时,设备缆线的长度不应小于1m。 3.7.8工业环境布线系统中间配线子系统设计应符合下列规定: 1 中间配线子系统信道应包括水平缆线、跳线和设备缆线(图3.7.8)。 设备 设备线缆 跳线 信道 设备线缆 图3.7.8 中间配线子系统构成 2 中间配线子系统链路长度计算应符合表3.7.8的规定。 表3.7.8中间配线子系统链路长度计算 连接模型 等 级 D E、EA F、FA ID互连-TO H=109-FX H=107-3-FX H=107-2-FX ID交叉-TO H=107-FX H=106-3-FX H=106-3-FX 注:1计算公式中:H为中间配线子系统电缆的长度(m);F为工作区设备缆线及ID处的设备缆线与跳线总长度(m);X为设备缆线的插入损耗(dB/m)与水平缆线的插入损耗(dB/m)之比;3为余量,以适应插入损耗值的偏离。 2 H的应用长度会受到工作环境温度的影响。当工作环境温度超过20℃时,屏蔽电缆长度按每摄氏度减少0.2%计算,非屏蔽电缆长度则按每摄氏度减少0.4%(20℃~40℃)和每摄氏度减少0.6%(>40℃~60℃)计算。 3 中间配线子系统信道长度不应大于100m;中间配线子系统链路长度不应大于90m;设备电缆和跳线的总长度不应大于10m,大于10m时中间配线子系统水平缆线的长度应适当减少;跳线的长度不应大于5m。 3.7.9 工业环境布线系统干线子系统设计应符合下列规定: 1 干线子系统信道连接方式及链路长度计算应符合本规范第3.3.3条第2款的规定。 2对绞电缆的干线子系统可采用D、E、EA、F、FA的布线等级。干线子系统信道长度不应大于100m,存在4个连接点时长度不应小于15m。 3光纤信道的等级及长度应符合表3.7.9的规定。 表3.7.9光纤信道长度 光纤 光纤等级 信道长度(m) 类型 波长(nm) 650 850 1300 1310 1550 OP1 OF-25、OF-50 双工连接 8.3 — — — — 塑料光纤 接续 — — — — — OP2 OF-100、OF-200 双工连接 15.0 46.0 46.0 — — 塑料光纤 接续 — — — — — OH1复合 OF-100、OF-200 双工连接 — 150.0 150.0 — — 塑料光纤 接续 — — — — — OM1、OM2、 OF-300、OF-500、 OF-2000 双工连接 — 214.0 500.0 — — OM3、OM4多模光纤 接续 — 86.0 200.0 — — OS1 OF-300、OF-500、 双工连接 — — — 750.0 750.0 单模光纤 OF-2000 接续 — — — 300.0 300.0 OS2单模光纤 OF-300、OF-500、OF-2000、OF-5000、 OF-10000 双工连接 — — — 1875.0 1875.0 3.8综合布线在弱电系统中的应用 3.8.1综合布线系统应支持具有TCP/IP通信协议的视频安防监控系统、出入口控制系统、停车库(场)管理系统、访客对讲系统、智能卡应用系统、建筑设备管理系统、能耗计量及数据远传系统、公共广播系统、信息导引(标识)及发布系统等弱电系统的信息传输。 3.8.2综合布线系统支持弱电各子系统应用时,应满足各子系统提出的下列条件: 1传输带宽与传输速率; 2缆线的应用传输距离; 3设备的接口类型; 4屏蔽与非屏蔽电缆及光缆布线系统的选择条件; 5 以太网供电(POE)的供电方式及供电线对实际承载的电流与功耗; 6各弱电子系统设备安装的位置、场地面积和工艺要求。 4光纤到用户单元通信设施 4.1 一般规定 4.1.1 在公用电信网络已实现光纤传输的地区,建筑物内设置用户单元时,通信设施工程必须采用光纤到用户单元的方式建设。 4.1.2 光纤到用户单元通信设施工程的设计必须满足多家电信业务经营者平等接入、用户单元内的通信业务使用者可自由选择电信业务经营者的要求。 4.1.3 新建光纤到用户单元通信设施工程的地下通信管道、配线管网、电信间、设备间等通信设施,必须与建筑工程同步建设。 4.1.4用户接入点应是光纤到用户单元工程特定的一个逻辑点,设置应符合下列规定: 1 每一个光纤配线区应设置一个用户接入点; 2 用户光缆和配线光缆应在用户接入点进行互联; 3 只有在用户接入点处可进行配线管理; 4 用户接入点处可设置光分路器。 4.1.5 通信设施工程建设应以用户接入点为界面,电信业务经营者和建筑物建设方各自承担相关的工程量。工程实施应符合下列规定: 1 规划红线范围内建筑群通信管道及建筑物内的配线管网应由建筑物建设方负责建设。 2建筑群及建筑物内通信设施的安装空间及房屋(设备间)应由建筑物建设方负责提供。 3用户接入点设置的配线设备建设分工应符合下列规定: 1)电信业务经营者和建筑物建设方共用配线箱时,由建设方提供箱体并安装,箱体内连接配线光缆的配线模块应由电信业务经营者提供并安装,连接用户光缆的配线模块应由建筑物建设方提供并安装; 2)电信业务经营者和建筑物建设方分别设置配线柜时,应各自负责机柜及机柜内光纤配线模块的安装。 4配线光缆应由电信业务经营者负责建设,用户光缆应由建筑物建设方负责建设,光跳线应由电信业务经营者安装。 5光分路器及光网络单元应由电信业务经营者提供。 6 用户单元信息配线箱及光纤适配器应由建筑物建设方负责建设。 7 用户单元区域内的配线设备、信息插座、用户缆线应由单元内的用户或房屋建设方负责建设。 4.1.6 地下通信管道的设计应与建筑群及园区其他设施的地下管线进行整体布局,并应符合下列规定: 1 应与光交接箱引上管相衔接。 2应与公用通信网管道互通的人(手)孔相衔接。 3 应与电力管、热力管、燃气管、给排水管保持安全的距离。 4应避开易受到强烈震动的地段。 5应敷设在良好的地基上。 6路由宜以建筑群设备间为中心向外辐射,应选择在人行道、人行道旁绿化带或车行道下。 7地下通信管道的设计应符合现行国家标准《通信管道与通道工程设计规范》GB 50373的有关规定。 4.2用户接入点设置 4.2.1 每一个光纤配线区所辖用户数量宜为70个~300个用户单元。 4.2.2 光纤用户接入点的设置地点应依据不同类型的建筑形成的配线区以及所辖的用户密度和数量确定,并应符合下列规定: 1 当单栋建筑物作为1个独立配线区时,用户接入点应设于本建筑物综合布线系统设备间或通信机房内,但电信业务经营者应有独立的设备安装空间(图4.2.2-1)。 |
联系我们
|
微信联系客服
![]() |
关于我们 | 联系我们 | 收费付款 |
服务热线:400-001-5431 | 电话:010-8572 5110 | 传真:010-8581 9515 | Email: bz@bzfyw.com | |
版权所有: 北京悦尔信息技术有限公司 2008-2020 京ICP备17065875号-1 51La |
本页关键词: |
GB 50311-2016, GB/T 50311-2016, GBT 50311-2016, GB50311-2016, GB 50311, GB50311, GB/T50311-2016, GB/T 50311, GB/T50311, GBT50311-2016, GBT 50311, GBT50311 |