YD/T 1092-2023 Telecommunication cables - Foamed polyolefin dielectric, corrugated copper-tube outer conductor, 50 Ohm radio-frequency coaxial cable for wireless communications
1 Scope
This document specifies product classification, requirements, test methods, inspection rules, packaging, transportation and storage requirements of foamed polyolefin dielectric, corrugated copper-tube outer conductor, 50 Ohm radio-frequency (RF) coaxial cable for wireless communications.
This document applies to the manufacture, testing and use of foamed polyolefin dielectric, corrugated copper-tube outer conductor, 50 Ohm radio-frequency (RF) coaxial cable for wireless communications, with the operating frequency range of 100~7125 MHz, (hereinafter referred to as “the cable”).
2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 2951.11 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties (GB/T 2951.11-2008, IEC 60811-1-1:2001, IDT)
GB/T 2951.13 Common test methods for insulating and sheathing materials of electric and optical cables - Part 13: Methods for general application - Measurement for determining the density - Water absorption tests - Shrinkage test (GB/T 2951.13-2008, IEC 60811-1-3:2001, IDT)
GB/T 3048.10 Test methods for electrical properties of electric cables and wires - Part 10: Spark test of extruded protective sheaths
GB/T 4909.2 Test methods for bare wires - Part 2: Measurement of dimensions
GB/T 6995.3 Markings for electric wires and cables - Part 3: Identifications of cables and wires
GB/T 11091 Copper strip for cables
GB/T 15065 Black polyethylene compounds for wire and cable
GB/T 17737.101 Coaxial communication cables - Part 1-101: Electrical test methods - Test for conductor d.c. resistance of cable (GB/T 17737.101-2018, IEC 61196-1-101: 2005, IDT)
GB/T 17737.102 Coaxial communication cables - Part 1-102: Electrical test methods - Test for insulation resistance of cable dielectric (GB/T 17737.102-2018, IEC 61196-1-102: 2005, IDT)
GB/T 17737.103 Coaxial communication cables - Part 1-103: Electrical test methods - Test for capacitance of cable (GB/T 17737.103-2018, IEC 61196-1-103: 2005, IDT)
GB/T 17737.105 Coaxial communication cables - Part 1-105: Electrical test methods - Test for withstand voltage of cable dielectric (GB/T 17737.105-2018, IEC 61196-1-105: 2005, IDT)
GB/T 17737.108 Coaxial communication cables - Part 1-108: Electrical test methods - Test for characteristic impedance, phase and group delay, electrical length and propagation velocity (GB/T 17737.108-2018, IEC 61196-1-108: 2005, IDT)
GB/T 17737.112 Coaxial communication cables - Part 1-112: Electrical test methods - Test for return loss (uniformity of impedance) (GB/T 17737.112-2018, IEC 61196-1-112: 2011, IDT)
GB/T 17737.201-2015 Coaxial communication cables - Part 1-201: Environmental test methods - Test for cold bend performance of cable (IEC 61196-1-201:2009, IDT)
GB/T 17737.313 Coaxial communication cables - Part 1-313: Mechanical test methods - Adhesion of dielectric and sheath (GB/T 17737.313-2015, IEC 61196-1-313: 2009, IDT)
GB/T 17737.317 Coaxial communication cables - Part 1-317: Mechanical test methods - Test for crush resistance of cable (IEC 61196-1-317: 2018, IDT)
GB/T 18380.12-2022 Tests on electric and optical fibre cables under fire conditions - Part 12: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame (IEC 60332-1-2: 2015, IDT)
GB/T 18380.35-2022 Tests on electric and optical fibre cables under fire conditions - Part 35: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C (IEC 60332-3-24: 2018, IDT)
GB/T 19849 Seamless copper-tube for cable
GB/T 21021.1 Intermodulation level measurement for passive RF and microwave devices - Part 1: General requirements and measuring methods (GB/T 21021.1-2021, IEC 62037-1:2012, IDT)
GB/T 21021.4 Intermodulation level measurement for passive RF and microwave devices - Part 4: Measurement of passive intermodulation in coaxial cables (GB/T 21021.4-2021, IEC 62037-4:2012, IDT)
GB T26125 Electrical and electronic products - Determination of six regulated substances (lead, mercury, cadmium, hexavalent chromium, polybrominated biphenyls, polybrominated diphenyl ethers) (GB/T 26125-2011, IEC 62321:2008, IDT)
GB/T 26303.1 Measuring method for dimensions and shapes of wrought copper and copper alloy - Part 1: Tube
GB/T 26303.3 Measuring methods for dimensions and shapes of wrought copper and copper alloys - Part 3: Sheets and strips
GB/T 29197 Copper-clad aluminum wire
GB/T 39560.8 Determination of certain substances in electrical and electronic products - Part 8: Phthalates in polymers by gas chromatography-mass spectrometry (GC-MS), gas chromatography-mass spectrometry using a pyrolyzer/thermal desorption accessory (Py/TD-GC-MS) (GB/T 39560.8-2021, IEC 62321-8: 2017, IDT)
YD/T 760 Polyolefin insulation materials for telecommunication cables
YD/T 837.3 Test methods for copper-core polyolefin-insulated aluminum-plastic integrated sheathed urban communication cables - Part 3: Test methods for mechanical and physical properties
YD/T 837.4 Test methods for copper-core polyolefin-insulated aluminum-plastic integrated sheathed urban communication cables - Part 4: Test methods for environmental performance
YD/T 837.5 Test methods for copper-core polyolefin-insulated aluminum-plastic integrated sheathed urban communication cables - Part 5: Test methods for cable structures
YD/T 1113 Low-smoke halogen-free compounds for telecommunication cables and optical fiber cable
JB/T 8137 Delivery drums for wires and cables
JB/T 12750 Multiply wood delivery drums for wires and cables
IEC 61169-4 Radio-frequency connectors - Part 4: RF coaxial connectors with inner diameter of outer conductor 16mm (0.63in) with screw lock - Characteristic impedance 50Ω (type7-16)
IEC 61196-1-113 Coaxial communication cables - Part 1-113: Electrical test methods - Test for attenuation constant)
3 Terms and definitions
No terms or definitions are identified for the purposes of this document.
4 Product classification
4.1 Product model
The product model consists of type code and gauge code. The type codes and their meanings are shown in Table 1. The gauge codes and their corresponding product sizes are shown in Table 2. See Annex A for codification description of common cable models and Annex B for their engineering service data.
Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Product classification
4.1 Product model
4.2 Product designation
5 Requirements
5.1 Cable construction
5.2 Inner conductor
5.3 Insulation
5.4 Outer conductor
5.5 Sheath
5.6 Cable performance requirements
5.7 Regulated substances
6 Test methods
6.1 Inner conductor
6.2 Insulation
6.3 Outer conductor
6.4 Cable sheath
6.5 Mechanical and physical properties and environmental performance of cable
6.6 Electrical performance test
6.7 Flame retardance test of flame retardant cable
6.8 Regulated substances
7 Inspection rules
7.1 End-of-manufacturing requirements
7.2 Product inspection
7.3 End-of-manufacturing inspection
7.4 Type inspection
8 Packaging, transportation and storage
8.1 Packaging
8.2 Transportation and storage
Annex A (Informative) Codification description for common cable models
Annex B (Informative) Engineering service data