1 Scope
This part of GB/T 6109 specifies the requirements of enamelled round copper winding wire of class 200 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin.
Note: A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance or application characteristics.
Class 200 is a thermal class that requires a minimum temperature index of 200 and a heat shock temperature of at least 220 °C.
The temperature in degrees Celsius corresponding to the temperature index is not necessarily that at which it is recommended that the wire be operated and this will depend on many factors, including the type of equipment involved.
The range of nominal conductor diameters covered by this part is:
— Grade 1: 0.050 mm up to and including 2.000 mm;
— Grade 2: 0.050 mm up to and including 5.000 mm.
The nominal conductor diameters are specified in Clause 4 of GB/T 6109.1-2008.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 6109. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this part. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 6109.1-2008 Enamelled Round Winding Wire — Part 1: General Requirements (IEC 60317-0-1:2005, IDT)
3 Definitions, General Notes on Methods of Test and Appearance
3.1 Definitions and general notes on methods of test
For definitions and general notes on methods of test see Clause 3 of GB/T 6109.1-2008.
In case of inconsistencies between GB/T 6109.1-2008 and this part, this part shall prevail.
3.2 Appearance
See 3.3 of GB/T 6109.1-2008.
Foreword II
1 Scope
2 Normative References
3 Definitions, General Notes on Methods of Test and Appearance
4 Dimensions
5 Electrical Resistance
6 Elongation
7 Springiness
8 Flexibility and Adherence
9 Heat Shock
10 Cut-through
11 Resistance to Abrasion (nominal conductor diameters from 0.250 mm up to and including 2.500 mm)
12 Resistance to Solvents
13 Breakdown Voltage
14 Continuity of Insulation
15 Temperature Index
16 Resistance to Refrigerants
17 Solderability
18 Heat or Solvent Bonding
19 Dielectric Dissipation Factor
20 Resistance to Transformer Oil
21 Loss of Mass
22 Pin Hole Test
30 Packaging