1 General
1.1 Scope
This part of GB/T 5013 specifies the particular specification for silicone rubber insulated cables of rated voltage of 300/500 V.
Each cable should comply with the appropriate requirements given in GB/T 5013.1 and the particular requirements of this part.
1.2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this part of GB/T 5013. For dated references, subsequent amendments to, or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB/T 2951.1-1997 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 1: Methods for General Application — Measurement of Thickness and Overall Dimensions — Section One: Tests for Determining the Mechanical Properties (idt IEC 60811-1-1:1993)
GB/T 2951.2-1997 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 2: Methods for General Application — Section Two: Thermal Ageing Methods (idt IEC 60811-1-2:1985)
GB/T 2951.5-1997 Common Test Methods for Insulating and Sheathing Materials of Electric and Optical Cables — Part 2: Methods Specific to Elastomeric Compounds — Section One: Ozone Resistance Test — Hot Set Test — Mineral Oil Immersion Test (idt IEC 60811-2-1:1986)
GB/T 3956 Conductors of Insulated Cables (GB/T 3956-1997, idt IEC 60228:1978)
GB/T 5013.1-2008 Rubber Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 1: General Requirements (IEC 60245-1:1998, IDT)
GB/T 5013.2-2008 Rubber Insulated Cables of Rated Voltages Up to and Including 450/750V — Part 2: Test Methods (IEC 60245-2:1998, IDT)
2 Heat Resistant Silicone Insulated Cable for a Conductor Temperature of Maximum 180℃
2.1 Code designation