1 Scope
This clause of GB 4706.1-1998 is replaced by:
This part of GB 4706 applies to the safety of electric heat pumps, including sanitary hot water heat pumps, air-conditioners, and dehumidifiers incorporating sealed motor-compressors, their maximum rated voltages being not more than 250V for single phase appliances and 600V for all other appliances.
Appliances not intended for normal household use but which nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this part.
The appliances referenced above may consist of one or more factory made assemblies. If provided in more than one assembly, the separate assemblies are to be used together, and the requirements are based on the use of matched assemblies.
Note 1: A definition of 'sealed motor-compressor' is given in IEC 60335-2-34.
Note 2: Requirements for refrigeration safety are covered by IS0 5149, and requirements for containers intended for storage of the heated water included in sanitary hot water heat pumps are, in addition, covered by IEC 60335-2-21.
Note 3: For appliances using flammable refrigerants, additional requirements are under consideration.
Supplementary heaters, or a provision for their separate installation, are within the scope of this standard, but only heaters which are designed as a part of the appliance package, the controls being incorporated in the appliance.
Note 4: Attention is drawn to the fact that
——for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary;
——for appliances intended to be used in tropical countries special requirements may be necessary:
——for appliances subjected to pressure, additionna1 requirements may be necessary;
——in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour, the national water supply authorities and similar authorities. In the case of appliances for permanent connection to the water supply system, all relevant requirements need to be observed.
Note 5: This part does not apply to
——humidifiers intended for use with heating and cooling equipment (IEC 60335-2-88);
——appliances designed exclusively for industrial processing;
——appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
Contents
Foreword I
IEC Foreword IV
1 Scope
2 Definitions
3 General Requirement
4 General Conditions for the Tests
5 Void
6 Classification
7 Marking and Instructions
8 Protection against Access to Live Parts
9 Starting of Motor-operated Appliances
10 Power Input and Current
11 Heating
12 Void
13 Leakage Current and Electric Strength at Operating Temperature
14 Void
15 Moisture Resistance
16 Leakage Current and Electric Strength
17 Overload Protection of Transformers and Associated Circuits
18 Endurance
19 Abnormal Operation
20 Stability and Mechanical Hazards
21 Mechanical Strength
22 Construction
23 Internal Wiring
24 Components
25 Supply Connection and External Cords
26 Terminals for External Conductors
27 Provision for Earthing
28 Screws and Connections
29 Creepage Distances, Clearances and Distances through Insulation
30 Resistance to Heat, Fire and Tracking
31 Resistance to Rusting
32 Radiation, Toxicity and Similar Hazards