Specification for YS Series Three-phase Asynchronous Motors
YS系列三相异步电动机技术条件 1 Scope
This standard specifies YS series three-phase asynchronous motor in terms of type, basic parameters and dimension, requirements, test methods, inspection rules and requirements for marking and packaging.
This standard is applicable to YS series three-phase asynchronous motor (frame size 45-90) (hereinafter referred to as motor), and all other series motors derived from YS series three-phase asynchronous motor may also refer.
2 Normative References
The following standards contain provisions which, through reference in this standard, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, the parties coming to an agreement based on this standard are encouraged to investigate whether the most recent editions of the standards apply. For undated references, the latest editions of the normative documents referred to apply.
GB/T 191-2000 Packaging - Pictorial Marking for Handling of Goods (eqv ISO 780:1997)
GB/T 1032-2005 Test Procedure for Three-phase Induction Motors
GB/T 2828.1-2003 Sampling Procedures for Inspection by Attributea - Part 1: Sampling Schemes Indexed by Acceptance Quality Limit(AQL) for Lot-by-Lot Inspection (ISO 2859-1:1999, IDT)
GB/T 4772.1-1999 Dimensions and Output Series for Rotating Electrical Machines - Part 1: Frame numbers 56 to 400 and Flange Numbers 55 to 1080 (idt IEC 60072-1:1991)
GB/T 4942.1-2006 Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code) - Classification (IEC 60034-5:2000, IDT)
GB 10069.1-2006 Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines Part 1: Method for the Measurement of Airborne Noise Emitted by Rotating Electrical Machines (ISO 1680:1999, MOD)
GB 12350-2000 Safety Requirements of Small-power Motors
GB/T 12665-1990 Requirements of Damp-heat Testing of Electrical Machine for Service in General Environmental Condition
JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines
JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for AC Low-voltage Machines
JB/T 10490-2004 Mechanical Vibration of Small Power Motors - Measurement,Evaluation and Limits of Vibration
3 Types, Basic Parameters and Dimensions
3.1 The protection level of motor enclosure adopts IP44, IP54 or IP55.
3.2 Method of cooling motor: IC 0141 for frame size ≥63; IC 0041 for frame size ≤56.
3.3 The construction and mounting type of motors shall meet the requirements of Table 1.