This standard specifies the types, basic parameters, technical requirements, assembling requirements, test methods and marking, packing, transportation and storage of the electrical submersible pump units. The electrical submersible pump units include submersible motor ("motor" for short), motor protect ("protect" for short), suction and processing units, submersible pump ("pump" for short), submersible cable ("cable" for short), special electrical submersible pump control cabinet ("control cabinet" for short), special electrical submersible pump transformer ("transformer" for short) and special electrical submersible pump junction box ("junction box" for short).
This standard is applicable to the design, manufacture, test and acceptance of electrical submersible pump units.
Foreword IV
1 Scope
2 Normative References
3 Terms and Definitions
4 Types and Models
4.1 Electrical submersible pump units
4.1.1 Types
4.1.2 Model designations
4.1.3 Applicable well temperature
4.1.4 Electrical submersible pump series
4.2 Motor
4.2.1 Type
4.2.2 Model designations
4.3 Protect
4.3.1 Types
4.3.2 Model designations
4.4 Suction and processing unit
4.4.1 Types
4.4.2 Model designations
4.5 Pump
4.5.1 Model designations
4.5.2 Selection of the pump discharge connector
4.6 Cable
4.6.1 Shape characteristic code
4.6.2 Insulant code
4.6.3 Sheath (including inner sheath) material code
4.6.4 Armored sheath code
4.6.5 Model designations
4.7 Transformer
4.7.1 Type
4.7.2 Model designations
4.7.3 Voltage
4.7.4 Additional winding
4.8 Control cabinet
4.8.1 Type
4.8.2 Model designations
4.9 Junction box
4.9.1 Type
4.9.2 Model designations
5 Requirements
5.1 Requirements for electrical submersible pump units
5.1.1 Underground working condition
5.1.2 Ground environmental conditions
5.2 Parts requirements
5.2.1 Motor
5.2.2 Protect
5.2.3 Suction and processing unit
5.2.4 Pump
5.2.5 Cable
5.2.6 Transformer
5.2.7 Control cabinet
5.2.8 Junction box
5.3 Vibration test
6 Test Method and Test Rules
6.1 Test Method
6.1.1 Selection requirements of instrument and meter
6.1.2 Motor
6.1.3 Protect
6.1.4 Electrical submersible pump units
6.1.5 Cable
6.1.6 Cable head
6.1.7 Transformer
6.1.8 Fixed-frequency control cabinet
6.1.9 Variable frequency control cabinet
6.1.10 Junction box
6.2 Test rules
6.3 Factory inspection
6.3.1 Motor
6.3.2 Protect
6.3.3 Suction and processing unit
6.3.4 Pump
6.3.5 Cable
6.3.6 Transformer
6.3.7 Control cabinet
6.3.8 Junction box
6.4 Preconditions of type inspection
6.5 Items for type inspection
6.5.1 Motor
6.5.2 Protect
6.5.3 Suction and processing unit
6.5.4 Pump
6.5.5 Cable
6.5.6 Transformer
6.5.7 Control cabinet
6.5.8 Sampling
7 Identification, protection, transport and storage
7.1 Identification
7.1.1 Nameplate of the motor
7.1.2 Nameplate of the protect
7.1.3 Nameplate of the suction and processing unit
7.1.4 Nameplate of the pump
7.1.5 Nameplate of the cable
7.1.6 Nameplate of the transformer
7.1.7 Nameplate of the control cabinet
7.2 Protection
7.3 Transport
7.4 Storage
Annex A (Informative) Calculation for the Maximum O.D. of the Routine Electrical Submersible Pump Unit
Annex B (Informative) The Minimum Insulation Resistance of Usual Cables