![]() |
中标分类
行业分类
ICS分类
最新标准
|
登录注册 |
您的位置: 标准明细 |
Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative. National Standards Technical Committee for Electrical Measuring Instruments (SAC/TC 104) is in charge of this English translation. In case of any doubt about the contents of English translation, the Chinese original shall be considered authoritative. The GB/T 17215.3 Electricity metering equipment (a.c.) – Particular requirements consists of the following parts under the general title: ——GB/T 17215.301 Part 1: Particular requirements for multi-function electricity meters; ——GB/T 17215.302 Part 2: Static harmonic meters for active energy; ——GB/T 17215.303 Part 3: Digital input electricity meters; ——GB/T 17215.304 Part 4: Static meters connected via electronic instrument transformer; ——GB/T 17215.311 Part 11: Electromechanical meter for active energy (classes 0.5, 1 and 2); ——GB/T 17215.321 Part 21: Static meters for active energy (classes 1 and 2); ——GB/T 17215.322 Part 22: Static meters for active energy (classes 0.2S and 0.5S); ——GB/T 17215.323 Part 23: Static meters for reactive energy (classes 2 and 3); ——GB/T 17215.324 Part 24: Static meters for reactive energy at fundamental frequency (classes 0.5S, 1S and 1); ——GB/T 17215.352 Part 52: Symbols. This part is Part 4 of GB/T 17215.3. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part and GB/T 17215.211-2006 Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 11: Metering equipment together form a series of associated national standards supporting the type test requirements of static meters connected via electronic transformer. Attention is drawn to the possibility that some of the elements of this standard may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights. This part was proposed by the China Machinery Industry Federation. This part was prepared by SAC/TC 104 National Standards Technical Committee for Electrical Measuring Instruments. Electricity metering equipment (a.c.) - Particular requirements - Part 4: Static meters connected via electronic transformer 1 Scope This part of GB/T 17215.3 specifies the terms and definitions, classification, technical requirements, accuracy classes and test methods of static meters connected via electronic transformer (hereinafter referred to as the "meters"). This part is only applicable to newly manufactured meters which have small (signal) analog input and are installed in the networks with a reference frequency of 50Hz or 60Hz to measure the a.c. electric energy and it applies to their type tests only. This part is applicable to the meters consisting of elements such as measuring unit and display enclosed together in a meter case. This part may be used as reference for the meters that have a small (signal) analog input only in the current circuit. This part is not applicable to the meters with digital inputs. Note: For the transformers to which the meters are intended to be connected, see GB/T 20840.7-2007, GB/T 20840.8-2007, and DL/T 1155-2012. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 15284-2002 Particular requirements for multi-rate electricity meters GB/T 17215.211-2006 Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 11: Metering equipment GB/T 17215.322-2008 Electricity metering equipment (a.c.) - Particular requirements - Part 22: Static meters for active energy (classes 0.2S and 0.5S) GB/T 17215.323-2008 Electricity metering equipment (a.c.) - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3) GB/T 17215.421-2008 Electricity metering equipment (a.c.) - Tariff and load control - Part 21: Particular requirements for time switches GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test GB/T 17626.11-2008 Electromagnetic compatibility - Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests GB/T 17626.29-2006 Electromagnetic compatibility - Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests GB/T 20840.2-2014 Instrument transformers - Part 2: Additional requirements for current transformers GB/T 20840.3-2013 Instrument transformers - Part 3: Additional requirements for inductive voltage transformers GB/T 20840.7-2007 Instrument transformers - Part 7: Electronic voltage transformers GB/T 20840.8-2007 Instrument transformers - Part 8: Electronic current transformers DL/T 1155-2012 Specification for non-traditional current and voltage transformers 3 Terms and definitions For the purposes of this document, the terms and definitions given in GB/T 17215.211-2006 and the following apply. 3.1 electronic transformer a generic term for electronic instrument transformers and non-traditional transformers 3.2 electronic instrument transformer a kind of device consisting of one or more current or voltage sensors that are connected to a transmission system and a secondary converter and used to transmit a quantity that is proportional to the quantity subjected to measurement so as to power the measuring apparatuses and meters and the relay protection or control devices [GB/T 20840.7-2007, definition 2.1.1] 3.3 current circuit a part of the internal connection and measuring units of the meter, of which the current characteristics are characterized by the small (signal) analog voltage UI applied to it Note: It is revised from the GB/T 17215.211-2006, definition 3.2.6. 3.4 voltage circuit a part of the internal connection and measuring units of the meter, of which the voltage characteristics are characterized by the small (signal) analog voltage UU applied to it Note: It is revised from the GB/T 17215.211-2006, definition 3.2.7. 3.5 extra-low voltage; ELV voltage between the conductors or between any conductor and earth, which does not exceed 50V a.c. or 120V ripple free d.c. (voltage band 1 as specified in GB/T 18379-2001) [GB 19212.1-2008, definition 3.7.15] 3.6 voltage correspond to starting current UI,st an analog voltage value that is continuously counted when the meter is started and characterizes the starting current 3.7 voltage correspond to rated current UI,n an analog voltage value that determines the relevant characteristics of the meter and characterizes the rated current 3.8 voltage correspond to maximum current UI,max an analog voltage value that characterizes the maximum current, with the meter being able to meet the accuracy requirements of this part 3.9 voltage correspond to reference UU,n an analog voltage value that determines the relevant characteristics of the meter and characterizes the reference voltage 4 Standard electric quantities and classification of meters 4.1 Standard electric quantities 4.1.1 Standard voltage correspond to reference See Table 1 for the standard voltage correspond to reference of the meter. Unless otherwise stated, the terms "voltage" and "current" refer to the root-mean-square values (r.m.s.). Table 1 Standard voltage correspond to reference In: V Voltage correspond to reference Standard value Exceptional value UU,n ; 2; ; 4 ; 1.625; ; 3.25; ; 6.5 4.1.2 Standard voltage correspond to rated current See Table 2 for the standard voltage correspond to rated current of the meter. Table 2 Standard voltage correspond to rated current In: V Voltage correspond to rated current Standard value Exceptional value UI,n 4 2 4.1.3 Voltage correspond to maximum current When the meter is operated via electronic current transformer, it shall be noted that the measuring range of the meter's current circuit matches the rated secondary output of the electronic current transformer. The voltage correspond to maximum current of the meter is 1.2UI,n, 1.5UI,n, 2UI,n, 4UI,n or 5UI,n, with 1.2UI,n as the preferred value. 4.1.4 Standard reference frequency The standard value of the reference frequency is 50Hz or 60Hz. 4.2 Classification of meters 4.2.1 According to the connection methods, the meters are classified into: ——three-phase three-wire meter; ——three-phase four-wire meter. 4.2.2 According to the accuracy classes, the meters are classified into: ——meter for active energy (class 0.2S); ——meter for active energy (class 0.5S); ——meter for reactive energy (class 2). Note: The class S meters have a measuring range of 1%UI,n~UI,max, so they shall be used together with special-purpose current transformers. For details of special-purpose current transformers, see GB/T 20840.8-2007, 12.2. 4.3 Electric quantity accumulation methods of meters The meter should accumulate and display the electric quantity with the standard value of the rated secondary current/voltage of electromagnetic transformer (see GB 20840.2-2014, 5.202 and GB 20840.3-2013, 5.301.2). However, other application methods are not excluded, for example, the meter accumulates and displays the electric quantity with the standard value of rated primary current/voltage of electronic transformer. 5 Mechanical requirements 5.1 General In addition to conforming to GB/T 17215.211-2006, Clause 5, the meters shall also meet the following requirements. 5.2 Marking of meters 5.2.1 Nameplate In addition to conforming to GB/T 17215.211-2006, 5.12, the meters shall also be marked with the following: a) Voltage correspond to reference: Example 1: 3×1.155/2V or 3×2.309/4V. b) Voltage correspond to rated current and voltage correspond to maximum current: Example 2: 4(4.8)V. c) The reference voltage, rated current and maximum current of the meter to accumulate and display the electric quantity are indicated in square brackets: Example 3: 3×1.155/2V[57.7/100V] or 3×2.309/4V[57.7/100V]; 4(4.8)V[1(1.2)A] or 4(4.8)V[5(6)A]. d) Voltage (value) of external power supply. e) The rated load range of the electronic transformer intended to be connected shall be marked. 5.2.2 Numbering of wiring terminal For each meter, the access circuit shall be permanently indicated, and the phase sequence, function and terminal number of such circuit shall be indicated in the circuit diagram. The terminal number shall be written in accordance with the rules that 2, 5 and 8 are for the voltage circuit, 1, 3; 4, 6; and 7, 9 for the current circuit, and 10 (11, 12) for the "earth". Foreword III 1 Scope 2 Normative references 3 Terms and definitions 4 Standard electric quantities and classification of meters 4.1 Standard electric quantities 4.2 Classification of meters 4.3 Electric quantity accumulation methods of meters 5 Mechanical requirements 5.1 General 5.2 Marking of meters 6 Climatic conditions 7 Electrical requirements 7.1 General 7.2 Measurement circuit 7.3 Power supply voltage influence 7.4 Short-time overvoltage influence of current circuit 7.5 Insulation 7.6 Electromagnetic compatibility 8 Accuracy requirements 8.1 Limits of error due to variation of voltage on the current circuit 8.2 Limits of error due to other influence quantities 8.3 Accuracy of clock (if any) 8.4 Combined error of electric energy indication (if any) 8.5 Demand indication error (if any) 8.6 Test of starting and no-load condition 8.7 Meter constant 8.8 Accuracy test conditions 9 Arrangement of test data Annex A (Normative) Test voltage waveforms for effect of voltage dips and short interruptions Annex B (Normative) Harmonic test Annex C (Informative) An accuracy test method Bibliography Figure A.1 Voltage interruption with △Ua.c.=100% for a period of 1s Figure A.2 Voltage interruption with △Ua.c.=100% for a period of one cycle of the rated frequency Figure A.3 Voltage dip with △Ua.c.=50% for a period of 1min Figure A.4 Voltage interruption with △Ud.c.=100% for a period of 1s Figure A.5 Voltage interruption with △Ud.c.=100% for a period of 0.3s Figure A.6 Voltage dip with △Ud.c.=60% for a period of 1s Figure B.1 Test circuit diagram Figure B.2 Amplitude of square wave Figure B.3 Amplitude of peaked wave Figure B.4 Burst fired waveform Figure B.5 (Incomplete) Fourier analysis of burst fired waveforms Figure C.1 Accuracy test method via a standard signal converter Bibliography Table 1 Standard voltage correspond to reference Table 2 Standard voltage correspond to rated current Table 3 External supply voltage Table 4 Percentage error limits (polyphase meters carrying balanced loads) Table 5 Percentage error limits (polyphase meters carrying single-phase load, but with balanced polyphase voltages applied to the voltage circuits) Table 6 Mean temperature coefficient limits of errors Table 7 Limits of variation in percentage error due to influence quantity Table 8 Square waveform Table 9 Peaked waveform Table 10 Value of D for the test of meter no-load condition Table 11 Voltage correspond to starting current 交流电测量设备 特殊要求 第4部分:经电子互感器接入的静止式电能表 1 范围 GB/T 17215.3的本部分规定了经电子互感器接入的静止式电能表(以下简称仪表)的术语和定义、分类、技术要求、准确度等级及其试验方法。 本部分仅适用于新制造的,安装在参比频率为50 Hz或60 Hz电网中测量交流电能的、小(信号)模拟量输入的仪表,并且仅适用于其型式试验。 本部分适用于测量单元和显示器等元件包封在同一表壳内的仪表。 仅在电流线路中采用小(信号)模拟量输入的仪表,可参照使用。 本部分不适用于数字量输入的仪表。 注:仪表预定连接的互感器参见GB/T 20840.7—2007、GB/T 20840.8—2007、DL/T 1155—2012。 2 规范性引用文件 下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。 GB/T 15284—2002 多费率电能表 特殊要求 GB/T 17215.211—2006 交流电测量设备 通用要求、试验和试验条件 第11部分:测量设备 GB/T 17215.322—2008 交流电测量设备 特殊要求 第22部分:静止式有功电能表(0.2S级和0.5S级) GB/T 17215.323—2008 交流电测量设备 特殊要求 第23部分:静止式无功电能表(2级和3级) GB/T 17215.421—2008 交流测量 费率和负荷控制 第21部分:时间开关的特殊要求 GB/T 17626.4—2008 电磁兼容 试验和测量技术 电快速瞬变脉冲群抗扰度试验 GB/T 17626.11—2008 电磁兼容 试验和测量技术 电压暂降、短时中断和电压变化的抗扰度试验 GB/T 17626.29—2006 电磁兼容 试验和测量技术 直流电源输入端口电压暂降、短时中断和电压变化的抗扰度试验 GB/T 20840.2—2014 互感器 第2部分:电流互感器的补充技术要求 GB/T 20840.3—2013 互感器 第3部分:电磁式电压互感器的补充技术要求 GB/T 20840.7—2007 互感器 第7部分:电子式电压互感器 GB/T 20840.8—2007 互感器 第8部分:电子式电流互感器 DL/T 1155—2012 非传统互感器技术条件 3 术语和定义 GB/T 17215.211—2006界定的以及下列术语和定义适用于本文件。 3.1 电子互感器 electronic transformer 对电子式互感器和非传统互感器的通称。 3.2 电子式互感器 electronic instrument transformer 一种装置,由连接到传输系统和二次转换器的一个或多个电流或电压传感器组成,用于传输正比于被测量的量,以供给测量仪器、仪表和继电保护或控制装置。 [GB/T 20840.7—2007,定义2.1.1] 3.3 电流线路 current circuit 仪表的内部接线和测量单元的一部分,施加其上的小(信号)模拟量电压UI表征线路的电流特性。 注:改写GB/T 17215.211—2006,定义3.2.6。 3.4 电压线路 voltage circuit 仪表的内部接线和测量单元的一部分,施加其上的小(信号)模拟量电压UU表征线路的电压特性。 注:改写GB/T 17215.211—2006,定义3.2.7。 3.5 特低电压 extra-low voltage;ELV 在导体之间或在任何导体与地之间的电压小于或等于交流50 V或无纹波直流120 V。(GB/T 18379—2001的电压区段1) [GB 19212.1—2008,定义3.7.15] 3.6 起动电流的电压 voltage correspond to starting current UI,st 仪表起动并连续计数的,表征起动电流的模拟量电压值。 3.7 额定电流的电压 voltage correspond to rated current UI,n 确定仪表有关特性的,表征额定电流的模拟量电压值。 3.8 最大电流的电压 voltage correspond to maximum current UI,max 仪表能满足本部分准确度要求的,表征最大电流的模拟量电压值。 3.9 参比电压的电压 voltage correspond to reference UU,n 确定仪表有关特性的,表征参比电压的模拟量电压值。 4 标准的电量值及仪表的分类 4.1 标准的电量值 4.1.1 标准参比电压的电压 仪表标准参比电压的电压见表1。除非另有说明,“电压、电流”术语是指方均根值(r.m.s.)。 表1 标准参比电压的电压 单位为伏特 参比电压的电压 标准值 例外值 UU,n ;2; ;4 ;1.625; ;3.25; ;6.5 4.1.2 标准额定电流的电压 仪表标准额定电流的电压见表2。 表2 标准额定电流的电压 单位为伏特 额定电流的电压 标准值 例外值 UI,n 4 2 4.1.3 最大电流的电压 当仪表经电子电流互感器工作时,需注意仪表电流线路的测量范围与电子电流互感器的额定二次输出相匹配。仪表最大电流的电压为1.2UI,n、1.5UI,n、2UI,n、4UI,n或5UI,n,其中1.2UI,n为优选值。 4.1.4 标准参比频率 参比频率的标准值为50 Hz或60 Hz。 4.2 仪表的分类 4.2.1 仪表按接线方式分为: ——三相三线; ——三相四线。 4.2.2 仪表按准确度等级分为: ——有功0.2 S级; ——有功0.5 S级; ——无功2级。 注:S级仪表的测量范围为1%UI,n~UI,max,因此,要与特殊用途的电流互感器配合使用。特殊用途电流互感器参见GB/T 20840.8—2007的12.2。 4.3 仪表累计电量的方式 仪表宜以电磁式互感器额定二次标准值(见GB 20840.2—2014的5.202和GB 20840.3—2013的5.301.2)累计并显示电量。但不排除其他方式的应用,例如,以电子互感器额定一次电流、一次电压标准值累计并显示电量。 5 机械要求 5.1 总则 除遵守GB/T 17215.211—2006的第5章的规定外,仪表还应满足下述要求。 5.2 仪表的标志 5.2.1 铭牌 除遵守GB/T 17215.211—2006的5.12的规定外,仪表还应标注: a) 参比电压的电压: 示例1: 3×1.155/2 V或3×2.309/4 V。 b) 额定电流的电压、最大电流的电压: 示例2: 4(4.8)V。 c) 在方括号中标注仪表累计并显示电量的参比电压、额定电流和最大电流: 示例3: 3×1.155/2 V[57.7/100 V]或3×2.309/4 V[57.7/100 V]; 4(4.8)V[1(1.2)A]或4(4.8)V[5(6)A]。 d) 外部供电的电压(值)。 e) 标注预定连接的电子互感器的额定负荷范围。 5.2.2 接线端子的编号 每台仪表应永久地标示接入的线路,接线圈中应标示出仪表接入线路的相序、功能和端子号。端子号的编写应遵从2、5、8为电压线路,1、3;4、6;7、9为电流线路,10(11、12)为“地”的规则。 6 气候条件 遵守GB/T 17215.211—2006的第6章的规定。 7 电气要求 7.1 总则 如果没有另行规定,仪表的电气要求遵守GB/T 17215.211—2006的第7章的规定。 7.2 测量线路 仪表经电子互感器工作时,其电压线路、电流线路的输入阻抗应与其连用的电子互感器的额定负荷相匹配,以取得正确的测量结果。电子互感器的额定负荷见GB/T 20840.7—2007中的5.2、GB/T 20840.8—2007中的5.4.3及DL/T 1155—2012中的5.1.4、5.2.4。 注:与额定负荷的匹配事宜也可在订货合同的技术规范中明确。 7.3 电源电压影响 7.3.1 供电电压 仪表的电压线路不提供电源,工作电源需由外部供电。 仪表的工作电源应从(电网)输电线路的被测量点获得供电,也可从独立的直流系统中获得供电。 采用特低电压供电的仪表,当特低电压从电网获得时,应通过一个安全隔离变压器或一个带分离绕组的转换器,此时安全隔离变压器和转换器的绝缘应符合双重绝缘或加强绝缘的要求。 在非有效接地系统或中性点不接地的星形配电网上使用的仪表,其交流供电的工作电源还应具有抗接地故障的能力。 推荐的交流或直流供电电压见表3,供电电压允许偏差-20%~+15%。 仪表的视在功率不应大于10 VA。 表3 外部供电电压 单位为伏特 流电压 直流电压 16 — 24 24 — 110 220 220 7.3.2 供电电压的电压暂降和短时中断 7.3.2.1 要求 供电电压的电压暂降和短时中断不应在计度器中产生大于x单位的改变,并且测试输出也不应产生大于x单位的(等效)信号。x值由式(1)算出: x=10-6mUnImax ………………………………(1) 式中: m——测量元件数; Un——累计电量的参比电压,单位为伏(V); Imax——累计电量的最大电流,单位为安(A)。 当电压恢复时,仪表的计量特性不应降低。 出于试验目的,仪表的计度器至少应具有0.01单位的分辨力。 7.3.2.2 交流电压供电的试验 试验应遵守GB/T 17626.11—2008,并在下列条件下进行: ——电源线路施加交流额定电压; ——线路通以参比电压的电压; ——电流线路无小(信号)模拟量电压UI。 交流电压供电的试验分为以下几项: a) 交流额定电压中断,ΔU交=100%。 1) 中断时间:1 s; 2) 中断次数:3次; 3) 中断间隔时间:50 ms,见附录A的图A.1。 b) 交流额定电压中断,ΔU交=100%。 1) 中断时间:额定频率的一个周期; 2) 中断次数:1次,见图A.2。 c) 交流额定电压暂降,ΔU交=50%。 1) 暂降时间:1 min; 2) 暂降次数:1次,见图A.3。 7.3.2.3 独立的直流系统供电的试验 试验应遵守GB/T 17626.29—2006,并在下列条件下进行: ——电源线路施加直流额定电压; ——电压线路通以参比电压的电压; ——电流线路无小(信号)模拟量电压UI。 独立的直流系统供电的试验分为以下几项: a) 直流额定电压中断,ΔU直=100%。 1) 中断时间:1 s; 2) 中断次数:3次; 3) 中断间隔时间:100 ms,见图A.4。 b) 直流额定电压中断,ΔU直=100%。 1) 中断时间:0.3 s; 2) 中断次数:3次; 3) 中断间隔时间:10 s,见图A.5。 c) 直流额定电压暂降,ΔU直=60%。 1) 暂降时间:1 s; 2) 暂降次数:3次; 3) 中断间隔时间:10 s,见图A.6。 7.4 电流线路的短时过电压影响 电流线路的短时过电压不成损坏仪表。当(保持通电状态下约1 h后)回到初始工作条件时,仪表应能正确工作,且在额定电流的电压和功率因数(或sinϕ)为1时,有功0.2S、0.5S级仪表的误差改变量不应超过0.05%;无功2级仪表的误差改变量不应超过1.0%。 试验线路应近似无感,仪表应逐相进行试验。 仪表应能经受20倍的最大电流的电压,即20UI,max,允许偏差为+0%~-10%,施加时间0.5 s的短时过电压试验。 7.5 绝缘 7.5.1 脉冲电压试验 除电源线路外,仪表的所有线路接地,脉冲电压试验仅在电源线路与地之间进行。 对于Ⅱ类防护仪表施加的试验电压为6 kV。 采用特低电压供电的仪表,施加的试验电压为2.5 kV。 试验中不应发生闪络、火花放电或击穿现象。 试验后,在参比条件下仪表的百分数误差的改变不应大于测量不确定度并对设备无机械损坏。 7.5.2 交流电压试验 交流电压试验的试验电压应近似正弦波,频率在45 Hz和65 Hz之间,施加1 min。电源容量至少应为500 VA。 除电源线路外,仪表的所有线路接地,交流电压试验仅在电源线路与地之间进行。 对于Ⅱ类防护仪表施加的试验电压为4 kV。 采用特低电压供电的仪表,施加的试验电压为1 kV。 试验均在盖上表壳和端子盖的情况下进行。 试验中不应发生闪络、火花放电或击穿现象。 试验后,在参比条件下仪表的百分数误差的改变应不大于测量不确定度并对设备无机械损坏。 7.6 电磁兼容性 7.6.1 总则 如果没有另行规定,电磁兼容性遵守GB/T 17215.211—2006的7.5的规定。 7.6.2 工作状态 仪表试验的工作状态定义为: ——电源线路通以额定电压; ——电压线路施加参比电压的电压UU,n; ——电流线路在无小(信号)模拟量电压UI时不应开路,或应接地;在有小(信号)模拟量电压UI时,施加额定电流的电压UI,n和按相应标准规定的功率因数值。 7.6.3 试验电压 7.6.3.1 电快速瞬变脉冲群抗扰度试验 电快速瞬变脉冲群抗扰度的试验应分别对电源线路、电流线路及电压线路,按GB/T 17626.4—2008中表1的试验等级4的规定进行。试验电压: ——在电源线路上的试验电压为4 kV; ——在特低电压的电源线路上的试验电压为1 kV; ——在电流线路和电压线路上的试验电压为2 kV。 7.6.3.2 浪涌抗扰度试验 浪涌抗扰度的试验应分别对电源线路、电流线路及电压线路进行。试验电压: ——在电源线路上为4 kV,发生器电源阻抗2Ω; ——在特低电压的电源线路上为2 kV,发生器电源阻抗10Ω; ——在电流线路和电压线路上为1 kV,发生器电源阻抗42Ω。 对于电压不大于60 V的直流输入端,如果是与交流电源的端口隔离而不会遭受瞬态过电压时,则无须对其进行浪涌试验。 7.6.3.3 无线电干扰抑制试验 无线电干扰抑制试验时,在电流线路中施加0.1倍~0.2倍的额定电流的电压,即0.1UI,n和0.2UI,n之间。 8 准确度要求 8.1 电流线路的电压改变量引起的误差极限 仪表在8.8规定的参比条件下,其百分数误差不应超过表4和表5中给定的相应准确度等级的极限[数值摘自GB/T 17215.322—2008、GB/T 17215.323—2008]。如果仪表是按测量双向电能设计的,则表4和表5的值应适用于每个方向。 在额定电流的电压UI,n和功率因数(或sinϕ)为1时,有功0.2S级、0.5S级和无功2级仪表,在平衡负载和不平衡负载时的百分数误差之差分别不应超过0.4%,1.0%和2.5%。 注1:当按表5试验时,电流线路的电压UI宜依次加入每一测量单元。 注2:本部分的功率因数角由电压线路的电压、电流线路的电压的相位差求得。 表4 百分数误差极限(带平衡负载的多相仪表) 电流线路的电压 功率因数 (或sinϕ) 各等级仪表百分数误差极限 有功 无功 0.2 S 0.5 S 2 0.01UI,n≤UI<0.05UI,n 1 ±0.4 ±1.0 — 0.02UI,n≤UI<0.05UI,n 1 — — ±2.5 0.05UI,n≤UI<UI,max 1 ±0.2 ±0.5 ±2.0 0.02UI,n≤UI<0.1UI,n 0.5L 0.8C ±0.5 ±0.5 ±1.0 ±1.0 — 0.05UI,n≤UI<0.1UI,n 0.5L或0.5C — — ±2.5 0.1UI,n≤UI≤UI,max 0.5L 0.8C ±0.3 ±0.3 ±0.6 ±0.6 — 0.5L或0.5C — — ±2.0 用户特殊要求时: 0.1UI,n≤UI≤UI,max 0.25L 0.5C ±0.5 ±0.5 ±1.0 ±1.0 — 0.25L或0.25C — — ±2.5 表5 百分数误差极限(带有单相负载的多相仪表,电压线路加平衡的多相电压) 电流线路的电压 功率因数 (或sinϕ) 各等级仪表百分数误差极限 有功 无功 0.2 S 0.5 S 2 0.05UI,n≤UI≤UI,max 1 ±0.3 ±0.6 ±3.0 0.1UI,n≤UI≤UI,max 0.5L(0.5C) ±0.4 ±1.0 ±3.0 8.2 由其他影响量引起的误差极限 8.2.1 总则 相对于8.8给出的参比条件下,仪表误差的平均温度系数极限不应超过表6的规定,由影响量变化引起的附加百分数误差不应超过表7规定的与准确度等级有关的极限[除电流和电压线路中的谐波分量,外部恒定磁场影响外,数值摘自GB/T 17215.322—2008、GB/T 17215.323—2008]。 应单独对某个影响量引起的改变量进行测试,所有其他影响量保持为参比条件。 表6 误差的平均温度系数极限 影响量 电流线路的电压 (平衡的,有说明除外) 功率因数(或sinϕ) 各等级仪表的平均温度系数%/K 有功 无功 0.2 S 0.5 S 2 整个工作温度范围应分成多个20K宽的子范围,在该范围中间的上10K和下10K进行侧定。然后在这些范围内确定平均温度系数 0.05UI,n≤UI≤UI,max 0.1UI,n≤UI≤UI,max 1 0.5L(0.5C) 0.01 0.02 0.03 0.05 0.10 0.15 表7 由影响量引起的百分数误差改变量极限 影响量 电流线路的电压 (平衡的,有说明除外) 功率因数 (或sinϕ) 各等级仪表百分数 误差改变量极限 有功 无功 0.2 S 0.5 S 2 0.9UU,n≤UU≤1.1UU,n 0.02UI,n≤UI≤UI,max 0.05UI,n≤UI≤UI,max 1 0.5L或0.5C — — 1.0 1.5 0.05UI,n≤UI≤UI,max 0.1UI,n≤UI≤UI,max 1 0.5L 0.1 0.2 0.2 0.4 — 工作电源由交流供电 0.8UU,n≤UU<0.9UU,n UI,n 1 0.3 0.6 3.0 1.1UU,n<UU≤1.15UU,n 工作电源由独立的直流系统供电 0.8UU,n≤UU<0.9UU,n UI,n 1 0.1 0.2 1.0 1.1UU,n<UU≤1.15UU,n UU=UU,n 供电电压为80%~115% 0.02UI,n 1 — — 0.5 0.01UI,n 0.05 0.1 — UU<0.8UU,n 且供电电压低于80% UI,n 1 +10~-100 a 频率改变量±2% 0.02UI,n≤UI≤UI,max 0.05UI,n≤UI≤UI,max 1 0.5L或0.5C — — 2.5 2.5 0.05UI,n≤UI≤UI,max 0.1UI,n≤UI≤UI,max 1 0.5L 0.1 0.1 0.2 0.2 — 逆相序 0.1UI,n 1 0.05 0.1 — 电压不平衡b UI,n 1 0.5 1.0 — 电流和电压线路中的谐波分量c 0.5UI,n 1 0.2 0.3 — 交流电流线路中的次谐波c 0.5UI,n 1 0.6 1.5 — 外部恒定磁感应c UI,n 1 0.5 0.75 3.0 外磁感应强度0.5 mTd UI,n 1 0.5 1.0 3.0 高频电磁场 UI,n 1 1.0 2.0 3.0 附件工作e 0.01UI,n 1 0.05 0.1 — 0.05UI,n — — l.0 射频场感应传导骚扰 UI,n 1 1.0 2.0 3.0 快速瞬变脉冲群 UI,n 1 1.0 2.0 4.0 阻尼振荡波 UI,n 1 1.0 2.0 4.0 a 此值为仪表的百分数误差。 b 有三个测量元件的多相仪表,如下面的相被断开,应在本表规定的以百分数误差表示的改变量的极限内测量和计数。 ——三相四线电网中的一相或两相; ——三相三线电网中(如果仪表为此工作设计)的三相中的一相。 本要求仅包括断相,不包括诸如互感器熔丝失效的事件。 c 试验条件按8.2.2~8.2.4规定。 d 外部0.5 mT的磁感应强度由施加给仪表电压相同频率的电流产生,并在对被测仪表最不利的相位和方向的条件下,仪表以百分数误差表示的改变量不应超过本表的规定值。 可使用中心能放置仪表的环形电流线圈产生该磁场。环形线圈的平均直径为1 m,截面为矩形,并且相对直径具有较小的径向厚度。磁场强度为400安匝。 e 该附件为封装在表壳内的并且是间断通电的,如:多费率计度器的电磁铁。 为能正确接线,最好标出与辅助装置的连接方法。若这种连接是插头和插座方式。它们宜是定(方)向连接的。仪表在最不利的接线下试验,其误差改变量不应超过车表规定值。 8.2.2 在有谐波情况下的准确度试验 8.2.2.1 总则 相对于8.8给出的参比条件,仪表的电流线路和电压线路中有谐波分量时,引起的附加百分数误差不应超过表7规定的与准确度等级有关的极限。试验在表8、表9指定的波形下进行。 8.2.2.2 方波的试验 方波的试验按附录B的图B.1所示的线路进行或采用能产生所要求波形的其他试验设备进行,试验的波形由表8给出的数据合成,电流线路中合成电压的波形幅值见图B.2。 试验按8.8的规定并在下列条件下进行: ——电压线路中基波电压等于UU,n; ——电流线路中基波电压等于0.5UI,n。 表8 方波波形 谐波次数 电流线路中电压幅值 电流线路中电压初相角 电压线路中电压幅值 电压线路中电压初相角 1 100% 0° 100% 0° 3 30% 0° 3.8% 180° 5 18% 0° 2.4% 180° 7 14% 0° 1.7% 180° 11 9% 0° 1.0% 180° 13 5% 0° 0.8% 180° 8.2.2.3 尖顶波的试验 顶波的试验按附录B的图B.1所示的线路进行或采用能产生所要求波形的其他试验设备进行,试验的波形由表9给出的数据合成,电流线路中合成电压的波形幅值见图B.3。 试验按8.8的规定并在下列条件下进行: ——电压线路中基波电压等于UU,n; ——电流线路中基波电压等于0.5UI,n。 表9 尖顶波波形 谐波次数 电流线路中电压幅值 电流线路中电压初相角 电压线路中电压幅值 电压线路中电压初相角 1 100% 0° 100% 0° 3 30% 180° 3.8% 0° 5 18% 0° 2.4% 180° 7 14% 180° 1.7% 0° 11 9% 180° 1.0% 0° 13 5% 0° 0.8% 180° 8.2.3 交流电流线路中的次谐波影响试验 次谐波影响试验按附录B的图B.1中的线路或采用可产生所要求波形的其他试验设备进行,脉冲串触发波形及其(不完全)傅里叶分析分别见图B.4、图B.5。 仪表在给定的试验波形和标准的试验波形下,测量的百分数误差改变量不应超过表7中的规定。 8.2.4 外部恒定磁感应影响试验 外部恒定磁场宜采用截面面积大于或等于2000 mm2的钕或铌永久磁铁获得,其磁感应强度在距离磁心表面30 mm处为200 mT±30 mT。该磁场作用于按正常(安装)使用时,仪表的所有可触及的表面。 在每块仪表的表面应选择六个试验点,仪表的最大误差改变量不应超过表7中的规定。 仪表可包含一个检测磁感应强度大于200 mT的报警装置。 8.3 时钟准确度(如果有) 遵守GB/T 17215.421—2008中对于“晶控时间开关”的所有要求及试验的规定。带有温度补偿的日历时钟计时误差,其随温度的改变量,每24 h应小于0.1 s/℃。 |
联系我们
|
微信联系客服
![]() |
关于我们 | 联系我们 | 收费付款 |
服务热线:400-001-5431 | 电话:010-8572 5110 | 传真:010-8581 9515 | Email: bz@bzfyw.com | |
版权所有: 北京悦尔信息技术有限公司 2008-2020 京ICP备17065875号-1 |
本页关键词: |
GB/T 17215.304-2017, GB 17215.304-2017, GBT 17215.304-2017, GB/T17215.304-2017, GB/T 17215.304, GB/T17215.304, GB17215.304-2017, GB 17215.304, GB17215.304, GBT17215.304-2017, GBT 17215.304, GBT17215.304 |