Glass-lined agitator - Gate type
1 Scope
This standard specifies the type, basic parameters, main dimensions, requirements, packaging, transportation and storage of the glass-lined gate agitator.
This standard is applicable to the gate agitator of the two pieces glass- lined steel vessel with agitator with a nominal volume of 50L-5000L, a design temperature of -20℃ - 200℃ and a nominal turning speed 50r/min - 80r/min.
2 Normative references
The following referenced documents are indispensable for the application of this document.
For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 25025 Specification of glass-lined equipment for industry
GB/T 25027 Two pieces glass-lined steel vessels with agitator
HG/T 2052 Drive for glass-lined vessel with agitator
3 Type, Basic parameters and Main dimensions
3.1 See Figure 1 for gate type glass-lined agitator’s type and see Table 1 for its basic parameters and main dimensions.
3.2 Four types of the agitator shaft end are as follows: ——A-type shaft end is compatible with the TB-type agitator given in HG/T 2052 ——B-type shaft end is compatible with the DJ-type agitator given in HG/T 2052 ——C-type shaft end is compatible with the DZ- and SZ-type agitator given in HG/T 2052 ——D-type shaft end is compatible with the SJ-type agitator given in HG/T 2052
3.3 Connection type and dimensions of the agitator shaft end ——See Figure 2 for A-type shaft end connection, and see Table 2 for its dimensions ——See Figure 3 for B-type shaft end connection, and see Table 3 for its dimensions ——See Figure 4 for C-type shaft end connection, and see Table 4 for its dimensions ——See Figure 5 for D-type shaft end connection, and see Table 5 for its dimensions
3.4 A-type shaft end is applicable to two-pieces glass-lined mixing vessel with agitator (KR reactor) with a nominal volume of 50L - 4000L as specified in GB/T 25027 and B, C and D-type shaft ends are suitable for KR reactor with a nominal volume of 1 000L- 5 000L. When the linear velocity at the end of the agitator's blade exceeds 5m/s, B-, C- or D-type shaft ends should be preferred