1 Scope
This standard specifies the method for detecting extractable carcinogenic dyestuffs (see Annex A) on printed textiles with high performance liquid chromatography - diode array detector (HPLC/DAD).
This standard is applicable to printed and dyed textiles.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections) to, or revisions of, any of these publications do not apply. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest editions apply.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods (GB/T 6682-1992, neq ISO 3696: 1987)
3 Theory
After the sample is extracted with methanol, the extract is subjected to qualitative and quantitative determination with the high performance liquid chromatography - diode array detector (HPLC/DAD).
4 Reagents and Materials
Unless otherwise specified, analytically-pure reagents and Grade 2 water (defined in GB/T 6682) are adopted for the purposes of this method.
4.1 Acetonitrile (Grade HPLC).
Foreword i
1 Scope
2 Normative References
3 Theory
4 Reagents and Materials
5 Instruments
6 Analytical Procedures
7 Result Calculation
8 Determination Lower Limit and Precision
9 Test Report
Annex A (Normative) Carcinogenic Dyestuffs and Detection Wavelength of HPLC/DAD Method
Annex B (Informative) HPLC/DAD Chromatograms of Carcinogenic Dyestuff Standard Sample at Different Detection Wavelengths