This standard specifies the test methods for hot air aging, ozone aging and artificial weathering accelerated aging (xenon arc lamp, carbon lamp and UV fluorescence lamp).
This standard is applicable to the comparison between the aging-resistant performance of pitch-based rolls and paints, high polymer rolls and paints used for building water proofing work. Other building water proofing materials may also adopt by reference.
1 Scope
2 Normative References
3 General Requirements
4 Hot Air Aging
5 Ozone Aging
6 Artificial Weathering Accelerated Aging (Xenon Arc Lamp)
7 Artificial Weathering Accelerated Aging (Carbon Arc Lamp)
8 Artificial Weathering Test (Ultraviolet Fluorescence-Condensing)
Appendix A (Normative) Determination of the Temperature Uniformity of Air Aging Test Chamber
Appendix B (Normative) Determination of the Wind Speed in the Air Aging Test Chamber
Appendix C (Normative) Determination of the Ventilation Rate of the Air Aging Test Chamber
Appendix D (Normative) Performance and Provision of Carbon Arc Lamp Light Source
Appendix E (Informative) Table of Air Density
Appendix F (Informative) Filter with Carbon Arc Lamp
Appendix G (Informative) Typical Carbon Arc Lamp Test Equipments