Codeofchina.com is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.
This standard is developed in accordance with the rules given in GB/T 1.1-2009.
This standard replaces TB/T 2311-2008 Surge protective devices for railway signal system. In addition to a number of editorial changes, the following main technical changes have been made with respect to TB/T 2311-2008:
——some terms and definitions of lightning protection devices are modified (see Clause 3; Clause 3 of Edition 2008);
——definition of voltage standing wave ratio of antenna feeder coaxial lightning arrester is added (see 3.36);
——the structure diagram of SPD is changed from hybrid representation method of component diagram and block diagram to block diagram only (see Figure 1; Figure 1 of Edition 2008);
——the classification method for SPD is modified; the definition and special requirements of SPD for railway signal system are specified and DC SPD for railway signal system is deleted (see 5.1; 5.2 of Edition 2008);
——capacity of terminals for connecting wire is modified (see 6.1.6; 6.1.5 of Edition 2008);
——requirements for the SPD disconnector of railway communication device are deleted (see 6.1.3 of Edition 2008);
——voltage protection level of parallel type AC power lightning protection box and the cooperation requirements for SPD and backup protection device are added (see 6.2.2);
——technical requirements for antenna feeder coaxial lightning arrester are added (see 6.2.5.2.3);
——test method for voltage protection level of parallel type AC power lightning protection box is added (see 7.3.1.3.4);
——cooperative test method for SPD and backup protection device in parallel type AC power lightning protection box is added (see 7.3.1.9);
——insulation resistance test for SPD connected to telecommunication and signaling circuits is added (see 7.3.3.3);
——test method for bit error rate of SPD connected to telecommunication and signaling circuits for digital circuits is added (see 7.3.3.6.2);
——capacitance test for SPD connected to telecommunication and signaling circuits is added (see 7.3.3.4):
——test method for antenna feeder coaxial lightning arrester is added (see 7.3.4.4.2);
——impulse waveforms for measured limiting voltage test of the SPD for railway signal system and the SPD connected to telecommunication and signaling circuits are modified (see 7.3.2.3.1 and 7.3.3.1.1; 8.4.3 of Edition 2008);
——test method for bit error rate of SPD connected to telecommunication and signaling circuits for digital circuits is added (see 7.3.3.6.2);
——temperature stability test for the terminal of lightning protection distribution cabinet is added (see 7.4.10);
——vibration test frequency range of outdoor type lightning protection device is modified (see 7.5.1; 8.7.1 of Edition 2008);
——test requirements for the nominal discharge current In for AC SPD used in low-voltage power circuit are deleted (see 8.4.5 of Edition 2008).
This standard was proposed by and is under the jurisdiction of Xi'an Railway Signal Research Co., Ltd.
The previous editions of the standard replaced by this standard are as follows:
TB/T 2311-1992, TB/T 2311-2002 and TB/T 2311-2008.
Lightning protection devices for electronic equipments in railway telecommunication, signaling, power supply systems
1 Scope
This standard specifies the terms and definitions, use environment, classification, technical requirements, test methods, inspection rules as well as marking, packaging, transportation and storage for synthetic lightning protection devices for electronic equipment in railway telecommunication, signaling, power supply systems with nominal AC voltage up to 1 000V (r.m.s. value) and DC voltage up to 1 500V.
This standard applies to lightning protection devices that limit the surges of indirect lightning effects and may be used by manufacturer for manufacturing and users for model selection. It applies to electronic equipment in railway telecommunication, signaling and power supply systems and may be referred by railway system and other department’s electrical and electronic equipment.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 2423.1-2008 Environmental testing - Part 2: Test methods - Tests A: Cold (IEC 60068-2-1:2007, IDT)
GB/T 2423.2-2008 Environmental testing - Part 2: Test methods - Tests B: Dry heat (IEC 60068-2-2:2007, IDT)
GB/T 2423.4-2008 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic ( 12h+12h cycle) (IEC 60068-2-30: 2005, IDT)
GB/T 2423.10-2008 Environmental testing for electric and electronic products - Part 2: Tests methods - Test Fc: Vibration (sinusoidal) (IEC 60068-2-6:1995, IDT)
GB/T 3482-2008 Lightning test method for electronic equipments
GB 4208-2008 Degrees of protection provided by enclosure (IP code) (IEC 60529:2001, IDT)
GB/T 5169.10-2006 Fire hazard testing for electric and electronic products - Part 10: Glow/hot-wire based test methods - Glow-wire apparatus and common test procedure (IEC 60695-2-10:2000, IDT)
GB/T 14048.7-2006 Low-voltage switchgear and controlgear - Part 7-1: Ancillary equipment - Terminal blocks for copper conductors (IEC 60947-7-1:2002, IDT)
GB/T 17627.1-1998 High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements (eqv IEC 61180-1:1992)
GB 18802.1-2011 Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests (IEC 61643-1:2005, MOD)
GB/T 18802.21-2004
(IEC 61643-21:2000, IDT) Low-voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
TB/T 2310 Gas discharge tube for the lightning protection of railway signaling equipments
TB/T 2312 Zinc oxide varistor for the lightning protection of railway signaling equipments
3 Terms, definitions and abbreviations
3.1 Definitions
For the purposes of this standard, the following terms and definitions apply.
3.1.1
lightning protection device
a general term for devices that limit lightning transient overvoltages and divert lightning surge currents
Note: It contains surge protection devices and their derivatives, as well as coaxial antenna feeder lightning protection device without any nonlinear voltage elements. Lightning protection device is also referred to as lightning arrester.
3.1.2
surge protection device, SPD
device that is intended to limit transient overvoltages and divert surge currents. It contains at least one nonlinear element
3.1.3
voltage limiting type SPD
SPD that has high impedance when no surge is present, but will reduce it continuously with increased surge current and voltage
Note: Common examples of elements used in voltage limiting type SPDs are varistors, suppressor diodes and other non-linear ones.
3.1.4
voltage switching type SPD
SPD that has high impedance when no surge is present, but can have a sudden change in impedance to a low value in response to a voltage surge
Note: Common examples of elements used in voltage switching type SPDs are gas discharge tubes, thyristors (silicon-controlled rectifiers) and bidirectional triode thyristors.
3.1.5
combination type SPD
SPD that incorporates both voltage switching elements and voltage limiting elements
3.1.6
one-port SPD
SPD is connected with the protected line in parallel. A one-port SPD may have separate input and output connections. No specific series impedance is inserted between these terminals
3.1.7
two-port SPD
SPD having two sets of ports, i.e. input and output terminals. There is specific series impedance connected between separate input and output terminals
3.1.8
multistage SPD
SPD with more than one voltage limiting elements; these voltage limiting elements may or may not be electrically separated by a series of elements; they may be either switching type or voltage limiting type
3.1.9
SPD used in low-voltage power circuits
SPD that limits the lightning transient overvoltage and overcurrent invading to the power supply equipment from the power feeder; including AC SPD used in low-voltage power circuits and DC SPD used in low-voltage power circuits.
3.1.10
AC power lightning protection box
power lightning protection device consisting of AC SPD used in low-voltage power circuits, SPD breaker, lightning counter, indicator light, and the power lightning protection device composed of alarm units to protect the power system from lightning overvoltage and overcurrent damage
3.1.11
SPD connected to telecommunication and signaling circuits
SPD for lightning overvoltage and overcurrent that limits the intrusion to information system device via signal transmission channels such as data line, signal line and communication line
3.1.12
antenna feeder lightning protection device
lightning protection device for antenna feeders of wireless communication equipment
3.1.13
maximum continuous operating voltage
UC
rated voltage of SPD
Note: Maximum continuous operating voltage of SPD refers to the DC voltage or r.m.s. value of maximum AC voltage, which may be continuously applied to the SPD. The maximum continuous operating voltage of a SPD connected to telecommunication and signaling circuits or a surge protective device for railway signal system is the maximum voltage r.m.s. value that can be continuously applied thereto without causing a drop in its transmission characteristics.
Foreword i
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Use environment conditions
5 Structure and classification of lightning protection devices
6 Technical requirements
7 Test methods
8 Inspection rules
9 Package, transportation and storage
Bibliography
铁路通信、信号、电力电子系统防雷设备
1 范围
本标准规定了交流额定电压不超过1 000 V(有效值)、直流电压不超过1 500 V的铁路信号、通信、电力电子系统设备综合防雷用防雷设备(以下简称防雷设备)的术语和定义、使用环境、分类、技术要求、试验方法、检验规则、标志、包装、运输和储存等。
本标准适用于对间接雷电效应的浪涌进行限制的防雷设备,可供制造商制造和用户选型使用。本标准适用于铁路信号、通信和电力控制系统的电气电子设备,铁路系统其他部门的电气电子设备可参照执行。
2规范性引用文件
下列文件对于本文件的应用是必不可少的。凡是注日期的引用文件,仅注日期的版本适用于本文件。凡是不注日期的引用文件,其最新版本(包括所有的修改单)适用于本文件。
GB/T 2423.1—2008 电工电子产品环境试验 第2部分:试验方法 试验A:低温(IEC 60068-2-1:2007,IDT)
GB/T 2423.2—2008 电工电子产品环境试验 第2部分:试验方法 试验B:高温(IEC 60068-2-2:2007,IDT)
GB/T 2423.4—2008 电工电子产品环境试验 第2部分:试验Db:交变湿热(12 h+12 h循环)(IEC 60068-2-30:2005,IDT)
GB/T 2423.10—2008 电工电子产品环境试验 第2部分:试验方法 试验Fc:振动(正弦)(IEC 60068-2-6:1995,IDT)
GB/T 3482—2008 电子设备雷击试验方法
GB 4208—2008外壳防护等级(IP代码)(IEC 60529:2001,IDT)
GB/T 5169.10—2006 电工电子产品着火危险试验 第10部分:灼热丝/热丝基本试验方法 灼热丝装置和通用试验方法(IEC 60695-2-10:2000,IDT)
GB/T 14048.7—2006低压开关设备和控制设备 第7-1部分:辅助器件 铜导体的接线端子排(IEC 60947-7-1:2002,IDT)
GB/T 17627.1—1998低压电气设备的高电压试验技术 第1部分:定义和试验要求(eqv IEC 61180-1:1992)
GB 18802.1—2011 低压电涌保护器(SPD) 第1部分:低压配电系统的电涌保护器 性能要求和试验方法(IEC 61643-1:2005,MOD)
GB/T 18802.21—2004 (IEC 61643-21:2000,IDT) 低压电涌保护器 第21部分:电信和信号网络的电涌保护器(SPD)性能要求和试验方法
TB/T 2310铁路信号设备雷电防护用气体放电管
TB/T 2312铁路信号设备雷电防护用氧化锌压敏电阻器
3术语、定义和缩略语
3.1 术语和定义
下列术语和定义适用于本文件。
3.1.1
防雷设备lightning protection device
限制雷电瞬态过电压和分流雷电浪涌电流的设备总称。
注:它包含浪涌保护器及其派生产品,以及不含任何非线性电压元件的同轴天馈线防雷设备等,也称为防雷器。
3.1.2
浪涌保护器SPD surge protection device
限制瞬态过电压和分流浪涌电流的设备,它至少包含一个非线性的元件。
3.1.3
电压限制型浪涌保护器 voltage limiting type SPD
没有浪涌时具有高阻抗,但随着浪涌电流和电压的上升,其阻抗将持续减小的浪涌保护器。
注:电压限制型浪涌保护器常使用压敏电阻器和抑制二极管等非线性元件。
3.1.4
电压开关型浪涌保护器voltage switching type SPD
没有浪涌时具有高阻抗,当对浪涌电压响应时能突变成低阻抗的浪涌保护器。
注:电压开关型浪涌保护器常使用气体放电管,晶闸管(可控硅整流器)和双向三极晶闸管等非线性元件。
3.1.5
复合型浪涌保护器combination type SPD
由电压开关型元件和电压限制型元件组成的浪涌保护器。
3.1.6
一端口浪涌保护器one-port SPD
浪涌保护器与被保护电路并联。可以具有分开的输入和输出端子,在这些端子之间没有特殊的串联阻抗。
3.1.7
二端口浪涌保护器two-port SPD
有两组端口,即输入、输出两组接线端子的SPD。在输入和输出端子之间有特殊的串联阻抗。
3.1.8
多级浪涌保护器 multistage SPD
具有不止一个限压元件的浪涌保护器。这些限压元件可以是被一系列元件在电气上分离开,也可以不是。这些限压元件可以是开关型,也可以是限压型。
3.1.9
电源浪涌保护器 SPD used in low-voltage power circuits
限制由电源馈线侵入电源设备的雷电瞬时过电压及过电流的浪涌保护器。包括交流电源浪涌保护器和直流电源浪涌保护器。
3.1.10
交流电源防雷箱AC power lightning protection box
由交流电源浪涌保护器、浪涌保护器用分断器、雷电计数器、指示灯及告警单元组成的具有防止电源系统遭受雷电过电压、过电流损害的电源防雷设备。
3.1.11
通道浪涌保护器 SPD connected to telecommunication and signaling circuits
限制由数据线、信号线及通信线等信号传输通道侵入信息系统设备的雷电过电压及过电流的浪涌保护器。
3.1.12
天馈防雷设备 antenna feeder lightning protection device
无线通信设备天馈线的防雷设备。
3.1.13
最大持续运行电压 maximum continuous operating voltage
UC
浪涌保护器的额定电压值。
注:电源浪涌保护器的最大持续运行电压是允许持久地施加在其上的最大交流电压有效值或直流电压。通道浪涌保护器或铁路信号设备浪涌保护器的最大持续运行电压是允许连续施加在其上而不致引起它传输特性下降的最大电压有效值。
3.1.14
放电管的直流点火电压DC spark-over voltage of gas discharge tube
UG
直流电压缓慢上升(100 V/s)时放电管发生击穿的电压值,它也是放电管的导通电压。由制造商规定的直流点火电压值称作“标称导通电压Un”。
3.1.15
压敏电阻的压敏电压 varistor voltage of metal oxide varistor
Uv
在规定温度和直流参考电流下测得的压敏电阻两端的电压值为压敏电阻的压敏电压Uv,它也是压敏电阻的导通电压。由制造商规定的压敏电压值称作“标称压敏电压Un”或“标称导通电压Un”,它指出了压敏电阻使用的条件和范围。
3.1.16
压敏电阻直流漏电流DC leakage current of metal oxide varistor
ILd
在规定温度和规定的直流电压下测得的流过压敏电阻的电流值。除非另有规定,测试电压值为0.75 Uv。
3.1.17
标称放电电流nominal discharge current
In
浪涌保护器不发生实质性破坏而能通过规定次数具有8/20μs波形的电流峰值,该值由浪涌保护器制造商规定。
3.1.18
最大放电电流 maximum discharge current
Imax
能够流过浪涌保护器且不造成浪涌保护器实质性损坏的、具有8/20 μs波形的电流峰值。Imax应大于In。
3.1.19
残压 residual voltage
Ures
放电电流通过浪涌保护器时,在其端子间的电压峰值。
3.1.20
限制电压 measured limiting voltage
施加规定波形和幅值冲击电流时,在浪涌保护器接线端子间测量到的残压最大值。
3.1.21
电压保护水平 voltage protection level
Up
表征浪涌保护器抑制浪涌能力的一个参数。
注:它由制造商从优选值列表中选择。本标准中所有浪涌保护器用波形为8/20 μs、幅值为标称放电电流In测试时的限制电压称为UIn,UIn不应大于Up。
3.1.22
额定负载电流rated load current
IL
两端口交流电源防雷设备的输出端能为被保护负载提供的最大持续交流有效值或直流电流值。
3.1.23
冲击放电电压 spark-over voltage with voltage impulse
Uimp
含气体放电管的浪涌保护器的线路端子与接地端子间施加上升速率为1 kV/μs的电压波冲击时,气体放电管发生击穿时的峰值电压。
3.1.24
电压降 voltage drop
△U
串联型电源浪涌保护器或电源防雷箱等防雷设备接入电源线路后,输出端电压降落和输入电压之比。
注:电压降用百分比表示。
3.1.25
暂时过电压试验值temporary overvoltage test value
UT
施加在电源浪涌保护器上,并持续一个规定时间的试验电压,以模拟在暂时过电压条件下的应力。
3.1.26
热崩溃thermal runaway
电源浪涌保护器承受的功率损耗超过外壳和连接器件的散热能力,引起内部元件温度逐渐升高,最终导致其损坏的过程。
3.1.27
热稳定thermal stability
在引起电源浪涌保护器温度上升的动作负载试验后,在规定的环境温度条件下,给电源浪涌保护器施加规定的最大持续工作电压,如果电源浪涌保护器的温度能随时间而下降,则认为电源浪涌保护器是热稳定的。
3.1.28
劣化degradation
由于浪涌、使用或不利环境影响造成电源浪涌保护器原始性能参数的变化。
3.1.29
浪涌保护器的脱离器SPD disconnector
把浪涌保护器从被保护线路断开所需的装置(内部的或外部的)。
注:这种断开装置不需要具有隔离能力,它防止系统持续故障并可用来给出浪涌保护器故障的指示。可包含多于一种的脱离功能,例如过电流保护功能和热保护功能。这些功能可以组合在一个装置中或由几个装置来完成。
3.1.30
外壳防护等级(IP代码)degrees of protection provided by enclosure(IP code)
外壳提供的防止触及危险的部件、防止外界的固体异物进入和防止水进入壳内的保护程度。
3.1.31
插入损耗 insertion loss
αe
由于在传输系统中插入一个浪涌保护器所引起的损耗。它是在浪涌保护器插入前传递到后面的系统部分的功率与浪涌保护器插入后传递到同一部分的功率之比。插入损耗通常用分贝(dB)来表示。
3.1.32
误码率bit error ratio
数据传输系统的浪涌保护器,在给定时间内,误码数与所传递的总码数之比。
3.1.33
传输频率transmission frequency
fG
通道浪涌保护器介入传输模拟信号的被保护系统传输线后,插入损耗不大于规定值的上限模拟信号频率。
3.1.34
绝缘电阻 insulation resistance
通道浪涌保护器指定端子之间施加最大持续运行电压Uc时呈现的电阻。
3.1.35
盲点 blind spot
高于最大持续运行电压Uc,但可以引起通道浪涌保护器不完全动作的工作点。即一个多级通道浪涌保护器在冲击试验时并不是所有各级都动作,这可能造成通道浪涌保护器中的一些元件遭受过载。
3.1.36
电压驻波比 voltage standing wave ratio
波传递从甲介质传导到乙介质,由于介质不同,波的能量会有一部分被反射。这种被反射的波与入射波叠加的后形成的波称为驻波。电压驻波比是指驻波的电压峰值与电压谷值之比,简称驻波比。
3.1.37
系统标称工作电压nominal voltage of the system
系统标称的工作电压值。交流电源系统是相线对中性线的电压标定值(有效值)Uo。直流电源系统是它的标称输出电压UN,通道防雷设备标称输出电压UN是被保护线路端口输出电压的有效值,它与直流电源系统标称输出电压一致。
3.1.38
凯文接线法V-connection
防雷设备与被保护线路并联的一种连接方法。被保护线路在防雷设备的同一接线端完成进入和离开,形成V字,使线路与端子的距离为零。也叫V形接线法。
3.2 缩略语
以下缩略语适用于本文件。
BER(Bit Error Ratio) 误码率
GDT(Gas Discharge Tube)气体放电管
MOV(Metal Oxide Varistor) 金属氧化物压敏电阻
PE(Protective Earth) 保护接地
SPD(Surge Protection Device)浪涌保护器
TOV(Temporary Over-Voltage) 暂时过电压
VSWR(Voltage Standing Wave Ratio) 电压驻波比
4 使用环境
SPD在下列环境条件下应能可靠的工作:
环境温度:室内受控环境:-5℃~+40℃;室外不受控环境:-40℃~+70℃;
相对湿度:室内受控环境:10%~80%;室外不受控环境:5%~96%;
大气压力:不低于70.1 kPa(相当于海拔3 000 m以下);交流电源SPD不低于54.0 kPa(相当于海拔5 000 m以下)。
5 防雷设备的分类和结构
5.1 防雷设备的分类
5.1.1 按用途分类
按用途分,防雷设备有下列类别。
5.1.1.1 电源防雷设备
电源防雷设备包括:
a) 交流电源SPD:一端口SPD,用于频率为48 Hz~62 Hz的单相或三相交流工频电源线的浪涌防护。
b) 直流电源SPD:一端口SPD,用于直流电源馈线的浪涌防护。
c) 交流电源防雷箱:用于频率为48 Hz~62 Hz的单相或三相交流工频电源线的浪涌防护,它有并联(一端口)和串联(二端口)两种。
5.1.1.2 数据传输和通信信号防雷设备
接入电信和信号网络的防雷设备包括通道SPD、天馈线同轴防雷器和铁路信号设备SPD,并应符合以下规定:
a) 通道SPD由一个或多个非线性元件组合而成。串联接入电信和信号网络的通道SPD由多个非线性元件组合而成多级两端口防雷器,其末级可以是纵向防护单元,也可以是横向防护单元。并联接入电信和信号网络的通道SPD是只有一级防护的一端口防雷器,采用的防雷器件可以是电压开关型、电压限制型和组合型。
b) 天馈线同轴防雷器专门用于无线天馈线的雷电防护,它包括仅含GDT的同轴SPD、高通滤波式同轴防雷器、1/4λ式同轴防雷器等。
c) 铁路信号设备SPD是接入铁路信号系统设备传输线(除转辙设备控制线外)的防雷设备,用于与铁路信号显示、联锁、闭塞等信号设备传输线与地线或传输线与传输线间的一端口SPD。它可以是复合型、电压开关型、电压限制型等。
5.1.2按接入电路方法分类
5.1.2.1 并联型:与被保护电路并联连接的一端口SPD或防雷箱。
5.1.2.2 串联型:与被保护电路串联连接的二端口SPD或防雷箱。
5.1.3按使用地点分类
5.1.3.1 室内型
安装在室内的防雷设备,使用在非暴露环境,雷电电磁环境较好。
5.1.3.2 室外型
安装在室外的防雷设备,使用在铁路站场、轨道道床内或轨边等暴露环境,雷电电磁环境较差。
5.2 防雷设备的结构
本标准所述防雷设备的结构如图1所示,图中显示了一端口防雷设备和二端口防雷设备。
一端口SPD并联接入电路,可以有两个端子、三个端子[图1中a)、b)、c)]。用凯文接法接入电路的一端口防雷设备,虽然有4个端子,但是输入和输出端子之间没有串联的阻抗,实际是并联接入被保护电路,列入三端子防雷设备中。二端口防雷设备输入和输出端子之间有串联的阻抗,它串联接入电路,可以有三个端子、四个端子、五个端子或多个端子[图1中d)、e)、f)、g)]。二端口防雷设备由一个或几个限压元件组成,并可包含限流元件。图1中图框上标有V的为限压型防雷设备,框图上标有V,I的为限压与限流组合型防雷设备。
a)并联型两端子防雷设备(差模保护)
b)并联型两端子防雷设备(共模保护)
c)并联型三端子防雷设备(共模保护)
V或V,I
三端子
d)串联型三端子防雷设备
e)串联型五端子防雷设备
f)串联型四端子防雷设备
g)串联型多端子防雷设备 (可无C端子)
说明:
V——限压元件;
V,I——限压元件与限流元件组合;
X1,X2,…,Xn-1,Xn——防雷设备线路侧(或外线侧)接线端子;
Y1,Y2,…,Yn-1,Yn——防雷设备被保护侧接线端子;
C——接地端子(公共端)。
图1 防雷设备的结构示意图
6 技术要求
6.1 整体要求
6.1.1 标识和标志
制造商至少应提供下列信息:
a) 制造商名或商标、型号;
b)安装位置类别;
c) 端口数量;
d) 安装方法;
e) 最大持续工作电压(每种保护模式有一个电压值);
f) 电压保护水平Up(每种保护模式有一个电压值);
g) 标称放电电流In;
h) 额定负载电流IL(如果需要);
i) 外壳防护等级(IP20时可以省略);
j) 电源SPD过电流保护推荐的最大额定值(如果适用时);
k)SPD脱离器动作指示;
l) 正常使用的位置(如果重要时);
m) 接线端的标志(如果需要);
n) 电缆进出线的标志(如果需要);
o) 安装说明(例如连接至低压系统、机械尺寸、导线长度等);
p) 电源SPD的电流类型:交流频率或直流,或二者都行;
q) 温度范围;
r) 交流电源SPD暂态过电压(TOV)特性;
s) 通道防雷器的传输特性(插损、使用频率范围、VSWR等);
t) 使用地点:室外型SPD本体上必须有明显的“室外型”标记,室内型可省略;
u) 天馈防雷器接头类别(例如N、BNC等);
v) 产品电路图;
w) 产品生产时应进行统一编号,该编号应具有唯一性,并应有相应的存档记录。
其中a)、e)、f)、g)、i)、s)应作为必备标志印制在防雷设备本体上,或持久地标贴在防雷设备本体上。
标志应不易磨灭且易于识别,不应标在螺钉和可拆卸的垫圈上。受空间限制时,制造商名称或商标和型号应标在防雷设备的本体上,其他标志可标在小包装上。