1 Subject Content and Application Scope
This standard specifies specific method to determine wear characteristic of petroleum hydraulic fluids in a high pressure constant volume vane pump.
This standard is applicable to determination of wear characteristic of petroleum hydraulic fluids.
2 Normative References
GB 1922 Solvent Naphthas
GB 3405 Petroleum Benzene
3 Summary of Test Method
11.4L of sample is cycled for 100h through the rotating vane pump and the operation condition is: 13720kPa±274.4kPa 1200r/min±60r/min; when the sample viscosity is 50.6mm2/s or lower than 50.6mm2/s at 40℃, the test temperature is 65.6℃±3℃; when the viscosity is larger than 50.6mm2s, the test temperature is 79.5℃±3℃. The total abrasion loss (mass loss millligram numbers of stator and the vane) of the pump is used as the test result. The total amount of the sample for a single test is 20L.
4 Equipments and Materials
4.1 Equipments
4.1.1 Driving system: minimum power is 11kW.
4.1.2 Removable pump core vane pump: 104C or 105C pump capacity is 28.4 at the conditions of 6860kPa, 1200r/min and 49℃.
4.1.3 Oil tank volume is 18.9L with a 60-mesh filter sieve at the outlet.
4.1.4 Pressure control valve at pump outlet.
4.1.5 Temperature control gear.
4.1.6 Temperature indicator: with appropriate sensor elements, used for indicating the inlet and outlet temperature of the pump.
4.1.7 Inlet and outlet pressure indicator of pump.
4.1.8 Heat exchange system (heating and cooling): minimum heat interchanging area is 1.4m2.
4.1.9 25μm middle oil filter.
4.1.10 Flow measuring device.
4.1.11 Low oil level, high and low temperature/pressure, low water pressure and motor overload safety systems.
4.2 Materials
4.2.1 Coal oil: in accordance with No.260 in GB 1922.
4.2.2 Benzol: in accordance with GB 3405.
4.2.3 Solvent naphthas: in accordance with requirements of No.190 in GB 1922.
Contents
1 Subject Content and Application Scope
2 Normative References
3 Summary of Test Method
4 Equipments and Materials
5 Reagents
6 Installation and Regulation of Test System
7 Preparation Work
8 Test Procedures
9 Precision
10 Report
Appendix A Vickers Pump Test table Frame Record (Additional)
Additional explanation: