Safety of household and similar electrical appliances - Part 76: Particular requirements for insect killers
1 Scope
This clause of GB/T 4706.1-2024 is replaced by the following.
This Standard deals with the safety of electric insect killers for household and similar purposes.
This document is applicable to household and similar electrical insecticides with a rated voltage not more than 250 V.
Appliances not intended for normal household use but that nevertheless may be a source of danger to the public, such as appliances intended to be used by laymen in shops, in light industry and on farms, are within the scope of this standard.
As far as is practicable, this standard deals with the common hazards presented by appliances that are encountered by all persons in and around the home. However, in general, it does not take into account
——persons (including children) whose
• physical, sensory or mental capabilities; or
• lack of experience and knowledge
prevents them from using the appliance safely without supervision or instruction;
——children playing with the appliance.
Note 101: Attention is drawn to the fact that
——for appliances intended to be used in vehicles or on board ships or aircraft, additional requirements may be necessary;
——in many countries additional requirements are specified by the national health authorities, the national authorities responsible for the protection of labour and similar authorities.
Note 102: This standard does not apply to
——appliances that function by emitting vaporized chemicals;
——appliances emitting ultrasonic waves;
——appliances intended to be used in locations where special conditions prevail, such as the presence of a corrosive or explosive atmosphere (dust, vapour or gas).
Note 103: For appliances provided with discharge lamps or tungsten filament lamps, IEC 60598-1 also applies as far as is reasonable.
2 Normative references
Addition:
IEC 60068-2-52:1996, Environmental testing - Part 2: Tests - Test Kb: Salt mist, cyclic
(sodium chloride solution)
3 Definitions
This clause of Part 1 is applicable except as follows.
3.1.9 Replacement:
normal operation
operation of the appliance under the following conditions:
——the output circuit is short-circuited;
——the grids are separated by the maximum distance for maintaining an arc, the appliance being operated in cycles consisting of 1 s of operation followed by a rest period of 2 s;
——a resistive load is connected between the grids and adjusted to obtain the maximum current.
3.101
insect killer
appliance that electrocutes insects by applying a voltage between two or more grids
3.102
effective irradiance
irradiance of electromagnetic radiation weighted according to a specific action curve